检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钟敬泉[1] Paul Dorian 高海青[1] 张薇[1] 黎莉[1] 钟明[1] 葛志明[1] 张梅[1] 季晓平[1] 王荣[1] 蒋桂花[1] 张运[1]
机构地区:[1]教育部与卫生部血管重构重点实验室山东大学齐鲁医院心内科,山东济南250012 [2]St Michael's Hospital of Toronto University,Canada
出 处:《山东大学学报(医学版)》2007年第4期343-347,共5页Journal of Shandong University:Health Sciences
基 金:山东省科技攻关项目(2004GG4402033;2006GG2202004);山东省自然科学基金项目(Y2006C52)
摘 要:目的:研究Oxylator,阻抗阈值瓣膜(ITV)以及Oxylator和ITV同时应用对血流动力学和冠脉灌注压(CPP)的影响。方法:将12头猪采用超速抑制刺激诱发室颤2 min后,立即予以3 min的心肺复苏(CPR)。在每头猪CPR时,监测随机应用手捏皮球、Oxylator、ITV以及Oxylator和ITV时的血流动力学变化和CPP。结果:①CPR时,手捏皮球、Oxylator、ITV、ITV+Oxylator的CPP分别为(21.6±1.98)、(25.2±2.08)、(30.7±2.56)和(22.7±2.06)mmHg,以ITV最高(P<0.05)。4种方法的左心室收缩压和主动脉收缩压无明显变化(P均>0.05);②累积除颤能量ITV组为(430±57.1)J,低于手捏皮球组(500±0)J、Oxylator组(860±0)J和ITV+Oxylator组(530±30.0)J(P<0.05)。结论:①4种方法的左室收缩压和主动脉收缩压无明显变化;②应用ITV的CPP最高,累积除颤能量最低,可能与该组的CPP高有关。Objective: To investigate the hemodynamics and coronary perfusion pressure(CPP) impacted by Oxylator and the impedance threshold valve (ITV) during cardiopulmonary resuscitation (CPR). Methods: ACD-CPR (active compression decompression CPR) was performed on twelve pigs in ventricular fibrillation (VF) models. After two minutes, each pig randomly received ITV, Manual, Oxyhor, or ITV combined with Oxylator during three minutes of ACD-CPR. Results: The CPP during CPR in Manual, Oxylator, ITV and ITV + Oxyaltor was (21.6 ±1.98)mmHg, (25.2±2.08)mmHg,(30.7 ±2.56)mmHg and (22.7±2.06)mmHg, respectively. There were no differences of left peak ventricular pressure and aortic peak pressure during the compression phase of CPR in Manual, ITV, Oxylator and ITV + Oxyaltor. The cumulative successful defibrillation energy in ITV, Manaul, Oxylator and ITV + Oxyaltor was (430±57.1) J, (500±0) J, (860±0) J and (530±30.0) J, respectively. Conclusions: (1) ITV+ Manual is the best for CPP among the four episodes. (2) There are no significant differences of left ventricular and aortic peak pressure during compression phase of CPR among the four episodes when ACD-CPR is used. The mean aortic pressure during CPR also is not significantly changed among the four episodes. (3) ITV + Manual is the best to defibrillate of the four episodes, probably because its CPP is the largest in this episode.
关 键 词:室颤 冠脉灌注压 血流动力学 心肺复苏 阻抗阈值瓣膜 猪
分 类 号:R320[医药卫生—人体解剖和组织胚胎学] R-332[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3