气相色谱火焰光度法测定低含量毒鼠强  被引量:2

Determining low content tetramine by using blaze luminosity in gas chromatography instrument

在线阅读下载全文

作  者:汪勇[1] 曾云康 涂小寒 

机构地区:[1]四川省遂宁市疾病预防控制中心,四川遂宁629000

出  处:《中国卫生检验杂志》2007年第7期1235-1236,共2页Chinese Journal of Health Laboratory Technology

摘  要:目的:探讨特殊样品中低含量毒鼠强的测定方法。方法:样品经氯仿提取、浓缩后,以气相色谱仪使用火焰光度检测器检测。结果:实验能达到的最低检测限为0.1 ng毒鼠强,回收率在92%~100%。结论:该检测方法简单、灵敏、快速、准确,是测定中毒样品中低含量毒鼠强的一种好的方法。Objective:To find the methods of determining the low content tetramine in the special patterns. Methods:After been distilled and condensed by the chloroform, the tetramine in the patters was determined by using Blaze luminosity in Gas chromatography instrument. Results :The lower limit was 0. 1 ng. The range of recycle percentage was 92% -100%. Conclusion:The method is simple, fast and nicety. It is a good method to determine the low content tetramine in patterns.

关 键 词:毒鼠强 火焰光度法 低含量 

分 类 号:R595.4[医药卫生—内科学]

 