作 者:吴丽[1] 周晓薇[1] 李红[1] 黄谷亮[1] 张思原[1]
机构地区:[1]广西大学轻工与食品工程学院,广西南宁530004
出 处:《化学试剂》2007年第12期727-729,732,共4页Chemical Reagents
基 金:广西科学基金资助项目(桂科基0575001)
摘 要:提出了用离子交换-电导检测离子色谱法测定煮糖罐积垢中主要阴离子的方法。选用9mmol/L NaOH溶液作为淋洗液,流速为1.00mL/min,可同时准确测定SO4^2-和PO4^3-含量。此方法相关性好(r≥0.9997),样品加标回收率分别为100.0%~102.2%和100.6%-103.4%,检出限分别为0.030μg/mL和0.048μg/mL。与国标法对比结果表明,该方法的准确度高,重现性好,操作简便。An ion-exchange chromatographic method was established to measure major anions in scale deposited in vacuum pan. 9 mmol/L of NaOH solution was selected as the eluent, and the contents of SO4^2- and PO4^3- could be determined exactly at a flow rate of 1.00 mL/min. It showed that this method had a good correlation ( r ≥ 0.999 7 ), the added standard recovery was 100.0% - 102.2% and 100.6% - 103.4%, respectively, and the detection limit was 0.030 μg/mL and 0.048 μg/mL, respectively. Compared with the results of national standard, the ion-exchange chromatography had better accuracy and reproducibility and it was easy to operate.