西昆仑山古里雅冰帽深钻孔冰温的稳定态分析  被引量:3

A Steady-state Analysis of Ice Temperature in the Guliya Ice Cap, West Kunlun Mountains

在线阅读下载全文

作  者:黄茂桓[1] 

机构地区:[1]中国科学院兰州冰川冻土研究所

出  处:《冰川冻土》1997年第3期202-206,共5页Journal of Glaciology and Geocryology

摘  要:在西昆仑山古里雅冰帽海拔6070m处钻孔,深309m,上部200m进行了温度测量。对实测资料作稳定态分析后,得出冰内温度梯度大、底部达融点的结果。算出地热通量为112mW/m2,与青藏高原为高地热区的观点一致。A borehole, 309 m in depth, was made at 6 070 m a s l. on the Guliya Ice Cap in the West Kunlun Mountains, of which in the upmost 200 m ice temperature was measured A steady-state analysis of the measured data reveals a great temperature gradient within the ice cap and the melting point appearing at the bottom. The geothermal flux is calculated to be 112 mW/m 2, which is coincident with the idea that the Tibetan Plateau is a high geothemal area.

关 键 词:冰帽 冰温 地热 稳定态 西昆仑山 冰川 