摘 要:利用PSV-400-M2(1.5MHz)高频型扫描式激光多普勒测振仪,对超声键合装置中受正弦激励、超声加载作用下的键合工具(劈刀),在不同松紧度下的稳态振动进行了连续扫描测试。结果表明,当劈刀连接的松紧度发生改变时,其稳态振动表现出不确定性;同一松紧度下振动形态中出现单节点,但不同松紧度下节点出现的位置不同;劈刀末端的速度振幅并不是人们期望的那样是最大。此外,基于弹性梁振动的基本理论对劈刀的稳态振动进行了探讨,得到其振动的近似模型。The sinusoidally excited vibration of bonding tool at measurement for a ultrasonic load was measured by continuously scanning laser Doppler vibrometer PSV-400-M2(1.5 MHz).The experimental phenomena and scanning testing results showed the steady-state vibration show uncertainty when the tightness changes;under the same tightness there is single-node in vibration,but under different tightness the node positions have changed;the velocity amplitude is not as the largest as expection.In addition,the mathematics modeling was carried out based on the vibration theory of flexible beam.