绝缘油击穿电压实验研究  被引量:5

Study of the experiment of breakdown of electric insulation oil

在线阅读下载全文

作  者:徐君[1] 张贤明[1] 韩敏[1] 张慧[1] 

机构地区:[1]重庆工商大学环境与生物工程学院,重庆400067

出  处:《重庆工商大学学报(自然科学版)》2008年第1期71-73,86,共4页Journal of Chongqing Technology and Business University:Natural Science Edition

基  金:重庆市自然科学基金项目(CSCT;2006BB2251;CSCT;2006BB0154)

摘  要:利用第3代SY型便携式绝缘油耐压试验仪,测定在不同温度、水分和机械杂质下,绝缘油介电强度的变化。结果表明:温度的升高能使绝缘油的击穿电压增大,当温度达到一定的时候,击穿电压开始下滑;而油中水分、机械杂质的增多,会使油液击穿电压有较明显的下降,因此在绝缘油运行前应该注意防潮、去杂。The variety of dielectric strength of insulating oil in different temperature, moisture, mechanical impurities with the third generation withstand voltage tester of the portable type SY model was measured. The result indicated that as the temperature became higher, the dielectric strength of insulating oil became stronger, that when the temperature rose to certain degree, the dielectric strength of insulating oil became to slip, and that, however, as moisture and mechanical impurities in insulating oil became greater, the dielectric down obviously. So, attention should be paid to moisture prevention and impurities removal.

关 键 词:绝缘油 介电强度 击穿电压 

分 类 号:TE626.35[石油与天然气工程—油气加工工程]

 