作 者:苗军[1] 夏群[1] 张继东[1] 唐树杰[1] 秦学联[2] 冯其金[1]
机构地区:[1]天津医院脊柱外科,300211 [2]天津中医药大学
出 处:《中华医学杂志》2008年第7期457-460,共4页National Medical Journal of China
摘 要:目的研究单纯植入椎间融合器(Cage)进行腰椎前路椎间融合的即刻与疲劳稳定性。方法6副人腰椎标本(L3-S1),L4以上和S1以下包埋固定,保留L4/L5和L5/S1两个间隙活动。首先作为空白组测试,随后于L5/S1间隙植入Cage作为实验组测试。即刻稳定性测试L4/L5、L5/S1椎体间在前屈、后伸、侧屈3个方向相对活动度。疲劳稳定性测试屈伸5万次后,Cage在L5/S1椎间隙中的相对位移。结果L5/S1植入Cage后在前屈、后伸、左侧屈3种运动下,椎间相对活动度分别为(0.83±0.26)°、(1.60±0.19)°和(0.72±0.20)°,明显小于空白组的活动度(3.60±0.30)°、(4.82±0.34)°和(3.80±0.28)°,差异均有统计学意义(均P〈0.01)。同时L4/L5椎间相对活动度代偿性增加,分别为(5.82±0.36)°、(5.38±0.30)°和(4.96±0.29)°,明显大于空白组(4.16±0.33)°、(4.02±0.30)°和(3.48±0.34)°,差异均有统计学意义(均P〈0.01)。5万次屈伸疲劳运动后,Cage与S1椎体间的相对位置无明显变化,相对位移为0。结论单纯应用Cage进行腰椎前路椎间融合,具有良好的即刻稳定性与疲劳稳定性。Objective To investigate the spinal segment instant and fatigue stability of anterior lumbar interbody fusion with stand-alone cage. Methods The vertebrae L4 and S1 of 6 human lumbar specimens ( L3 - S1 ) were embedded with dental base acrylic resin powder and fixed on mechanical machine, and the L4/L5 and L5/S1 disk spaces were left active. The 6 specimens underwent mechanical test as control group first, and then used as experimental group with a cage implanted in L5/S1. Instant instability was tested in three directions: flexion, extension, and lateral bend. The relative movement of L4/L5 and L5/S1 was recorded. Fatigue instability was tested after 50 000 times of flexion-extension movement, and the relative displacement between the cage and S1 was recorded. Result In the three directions of flexion, extension, and lateral bend, the relative movements of L5/S1 in the experimental group were 0. 83 ± 0. 26°, 1.60 ± 0. 19°, and 0. 72 ± 0. 20° respectively, all significantly decreased than those of the control group (3. 60 ± 0. 30°, 4. 82 ± 0. 34°, and 3.80 ± 0. 28° respectively, all P 〈 0. 01 ). The relative movement of L4/L5 of the experimental group were 5. 82 ± 0. 36°,5.38 ±0. 30°, and 4. 96 ±0. 29°in the three directions respectively, all significantly higher than those of the control group (4. 16 ±0.33°, 4.02 ±0.30°, and 3. 48 ±0. 34° respectively, all P 〈 0. 01 ). After 50 000 times of flexion-extension fatigue movement, the relative displacement between the cage and S, was zero. Conclusion Anterior lumbar interbody fusion with a stand-alone cage has excellent instant and fatigue stability, which can provide enough stability for clinical bone fusion without other internal fixation.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222