前列腺抗原酶促化学发光免疫分析方法学的建立  被引量:3

Chemiluminescence Immunoassay for Prostate-Specific Antigen

在线阅读下载全文

作  者:张雪峰[1] 刘一兵[1] 贾娟娟[1] 许文革[1] 李子颖[1] 陈永利[1] 韩世泉[1] 

机构地区:[1]中国原子能科学研究院同位素研究所,北京102413

出  处:《原子能科学技术》2008年第2期112-116,共5页Atomic Energy Science and Technology

摘  要:应用鲁米诺-过氧化氢发光体系建立定量测定血清前列腺特异性抗原含量的酶促化学发光免疫分析方法。该方法测量范围为1.5~80μg/L,灵敏度为0.12μg/L,批内变异<5%,批间变异<15%。回收率为83.8%~118.7%,稀释实验测定值与稀释度呈线性相关,相关系数为0.999。本方法与免疫放射分析方法的相关方程y=1.07x+0.68,相关系数r=0.97。The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0. 999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y= 1. 07x+0. 68, and correlation coefficient r= 0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity.

关 键 词:酶促化学发光免疫分析方法 前列腺特异性抗原 单克隆抗体 

分 类 号:R697.3[医药卫生—泌尿科学]

 