柱切换HPLC法直接测定人尿中咖啡因的含量  被引量:5

Determination of Caffeine in Human Urine by Column Switching HPLC

在线阅读下载全文

作  者:朱绍棠 杨树民 王小兵 

机构地区:[1]国家体委运动医学研究所

出  处:《药物分析杂志》1997年第5期329-331,共3页Chinese Journal of Pharmaceutical Analysis

摘  要:用柱切换高效液相系统直接进样测定人尿中咖啡因的含量,尿样中咖啡因的回收率大于98%,最低检测浓度可达到0.2mg/L。同时与液相提取测定咖啡因的方法进行了比较,结果表明,直接进样法测定咖啡因不仅方法简便,而且减少了提取过程所造成的损失,使定量结果更加准确可靠。A HPLC method with column switching has been developed for detection of caffeine in human urine.The urine sample was directly injected into a precolumn after 3 5min,column switch,the concentrated caffeine was eluted into an analytical column.Caffeine was detected by a diode-array detector at 275nm.The recoveries of the method were above 98%.The relative standard deviation was 0 21%~0 64%.The detection limit was 0 2mg/L.The method is sensitive enough for doping analysis and has been successfully used in the doping control.

关 键 词:高效液相色谱 咖啡因 柱切换 兴奋剂检测 HPLC 

分 类 号:R927.2[医药卫生—药学] R971.7

 