检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国检验检疫科学研究院食品安全研究所,北京100025
出 处:《中国卫生检验杂志》2008年第3期393-395,428,共4页Chinese Journal of Health Laboratory Technology
基 金:国家质量监督检验检疫总局课题"塑料食品包装材料中有毒物质系统检测方法研究及卫生安全评价"(2006IK111)
摘 要:目的:建立气相色谱质谱联用法测定与食品接触的塑料成型品中的邻苯二甲酸酯类增塑剂。方法:水性模拟液(水、3%乙酸溶液和10%乙醇溶液)用正己烷进行萃取,脂肪模拟液异辛烷采用正己烷稀释后直接进样。结果:该方法在4种模拟物浸泡液中,回收率为80.0%-108.0%,相对标准偏差小于7.47。结论:该方法灵敏度高、定量准确、重现性好,测定低限能够满足国际限量要求。Objective :To establish a new method for determination of phthalates from plastic articles in food simulants by GC/ MS. Methods :The aqueous simulant (distilled water, 3% (w/v) acetic acid aqueous solution, 10 % (v/v) ethanol aqueous solution) test samples were extracted with n - hexane and isooctane was diluted by n - hexane for injection directly. Results: In four simulants, the rate of recovery was between 80. 0% and 108.0% and RSD less than the reference value 7.47. Conclusion:This method has good sensitivity, accuracy, repeatability. The limit of quantitation of this method can meet the international standard.