Experimental verification of therapeutic doses for the superficially-placed tumor radiotherapy with heavy ions at HIRFL  被引量:2

Experimental verification of therapeutic doses for the superficially-placed tumor radiotherapy with heavy ions at HIRFL

在线阅读下载全文

作  者:刘新国 李强 吴庆丰 陶家军 金晓东 

机构地区:[1]Institute of Modern Physics, Chinese Academy of Sciences [2]Graduate University of Chinese Academy of Sciences

出  处:《Chinese Physics C》2009年第2期151-155,共5页中国物理C(英文版)

基  金:Supported by Century Program of Chinese Academy of Science (O506120BR0);National High Technology Research and Development Program of China (863 Program, 2006AA02Z499)

摘  要:Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80--100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally therapeutic dose distributions was conducted under the condition of simulating patient treatment in the therapy terminal at HIRFL. The measured depth-dose distributions basically coincide with the expected ones. These results indicate that the irradiation system and the dose optimization method are effective in the ongoing carbon-ion radiotherapy for shallow-seated tumors at HIRFL.Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80--100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally therapeutic dose distributions was conducted under the condition of simulating patient treatment in the therapy terminal at HIRFL. The measured depth-dose distributions basically coincide with the expected ones. These results indicate that the irradiation system and the dose optimization method are effective in the ongoing carbon-ion radiotherapy for shallow-seated tumors at HIRFL.

关 键 词:heavy-ion radiotherapy carbon ions therapeutic dose verification irradiation system dose optimization 

分 类 号:R730.5[医药卫生—肿瘤]

 