低分子肝素活性测定中生物统计的应用  被引量:1

Evaluation the potency of low-molecular-weight heparin by bio-statistical methods

在线阅读下载全文

作  者:王文杰[1] 韩冬云[1] 张秀梅[1] 

机构地区:[1]吉林华康药业股份有限公司,敦化133700

出  处:《药物分析杂志》2009年第2期272-274,共3页Chinese Journal of Pharmaceutical Analysis

摘  要:目的:对低分子肝素(LMWH)生物活性(抗-FⅩa和抗-FⅡa)测定中几种生物统计方法进行探讨。方法:LMWH生物活性测定采用发色底物分光光度法,运用量反应平行线原理生物统计,比较几种实验设计、统计方法,检测实验可靠性、计算效价、精密度的差异。结果:发色底物分光光度法的量反应平行线法几种实验设计、统计方法结果相似,其差异无统计学意义(P>0.05)。结论:对LMWH的抗-FⅩa和抗-FⅡa效价测定采用发色底物分光光度法;以量反应平行线法进行分析中。在符合标准规定前提下,几种生物统计方法和实验设计都可应用。Objective: Discussion of bio - statistical methods for anti - factor Xa or anti - factor IIa of low - molecu- lar - weight heparin ( LMWH ) evaluation. Method: Chromogenic assay was used for bio - activity of LMWH by quantity response parallel line analysis. Different bio - statistical methods and design were compared for experimen- tal reliability examination, potency and precise in analysis results. Results: The differences of several bio - statistical methods and design by parallel line analysis were small and not statistically significant ( P 〉 0.05 ). Conclusion : Several bio- statistical methods and design could be used in validation of the anti -factor Xa or anti -factor Ⅱa chromogenic assays for the potency assessment of LMWH by parallel line analysis, when the results conforms to the standard.

关 键 词:低分子肝素 效价测定 生物统计 

分 类 号:R917[医药卫生—药物分析学]

 