摘 要:指出提高数据采集系统的精度仅仅依靠提高信号幅值的精度是不够的,还应保证采样间隔的精度和采样同步性,提出了保证采样间隔精度的措施.通过触发同步和精确定时,实现了对信号起点的精确采集,保证了连续采集时采样间隔的精确性和恒等性.To enhance the accuracy of the data acquisition system besides increasing the accuracy of the amplitude of the signals it is also necessary for ensuring the accuracy of the scanning duration and synchronisation of scanning. Thus the measure of ensuring the accuracy of scanning duration is stated. By using trigger synchronous and precise timing, the accurate acquisition on the starting point of the signal is implemented. The precision and identity of the scanning duration in continuous data acquisition are ensured.
分 类 号:TP274.2[自动化与计算机技术—检测技术与自动化装置]