检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马丽英[1] 姜吉刚[1] 冯霞光[2] 王怀友[2]
机构地区:[1]滨州医学院化学教研室,山东烟台264003 [2]山东师范大学化学化工与材料科学学院,山东济南250014
出 处:《化学工程师》2009年第3期24-26,共3页Chemical Engineer
基 金:山东省自然科学基金项目(Y2006B31)
摘 要:在用乙酰丙酮-甲醛作荧光衍生试剂测定胺类物质时,由于试剂背景干扰,胺类物质无法准确测定。本文以盐酸普鲁卡因为例,研究了同步荧光光度法测定胺类物质消除背景干扰的条件。同法测定了苯丙氨酸、正丙氨、正丁氨、谷氨酸、色氨酸和亮氨酸,给出了上述物质的线性回归方程,检出限,回收率和分析条件。Because of the interference of background of acetylacetone-formaldehyde, some primary aminecontaining compounds cannot be determined by normal fluorimetry using acetylacetone-formaldehyde as the fluorigenic reagent. The procaine hydrochloride was studied as a sample in the synchronous fluorimetry using acetylacetone-formaldehyde as the fluofigenic reagent and the background of acetylacetone-formaldehyde was eliminated without separation. Some primary amine-containing compounds, such as procaine hydrochloride, L-phenylalanine, n-propylamine, n-butylamine, L-Glutamic acid, DL-trytophan and L-leucine can be determined by synchronous fluorimetry. The linear regression equations of calibration graph, detection limits, recoveries and optimum condition were listed.