A Simple and Sensitive Liquid Chromatographic Technique for the Determination of Cefotetan Disodium in Human Plasma and Its Application in a Pharmacokinetic Study  被引量:2

A Simple and Sensitive Liquid Chromatographic Technique for the Determination of Cefotetan Disodium in Human Plasma and Its Application in a Pharmacokinetic Study

在线阅读下载全文

作  者:刘亚妮 黄建耿 刘金梅 马林 吕永宁 师少军 

机构地区:[1]Clinical Trial Organization for Pharmaceutical Products,Union Hospital,Tongji Medical College,Huazhong University of Science and Technology [2]Department of Pharmaceutics,School of Pharmacy,Tongji Medical College,Huazhong University of Science and Technology

出  处:《Journal of Huazhong University of Science and Technology(Medical Sciences)》2012年第5期779-784,共6页华中科技大学学报(医学英德文版)

基  金:supported by a grant of the Guangzhou Boji Clinical Research Center of New Drugs,Guangzhou,Guangdong,China

摘  要:A simple and sensitive liquid chromatographic method was developed for quantification of cefotetan disodium (CTT),a semi-synthetic cephamycin antibiotic,in human plasma.CTT and the internal standard chloramphenicol were extracted from plasma by a simple one-step protein precipitation with 35% (v/v) perchloric acid.Separation was carried out on a reverse-phase C18 column with a mobile phase of acetonitile-water containing 0.5% (v/v) phosphoric acids (20:80,v/v) at a flow rate of 1.0 mL/min.The column effluent was monitored by UV detection at 300 nm.The column temperature was maintained at 40°C.This method demonstrated good linearity in the range of 0.525-300.0 μg/mL,with correlation coefficients greater than 0.99.The limit of quantification (LOQ) was 0.525 μg/mL in human plasma.Intra-and inter-day precisions were less than 6.63% in terms of relative standard deviation (RSD).The accuracy,when expressed by the bias,ranged from 0.57% to 4.04%.The mean extraction recovery of CTT was higher than 40.94%.The method was found to be precise,accurate,and specific for CTT quantitative analysis,and was successfully applied for a pharmacokinetic study of CTT after a single intravenous dose of 1.0 g of CTT in healthy Chinese subjects.A simple and sensitive liquid chromatographic method was developed for quantification of cefotetan disodium (CTT),a semi-synthetic cephamycin antibiotic,in human plasma.CTT and the internal standard chloramphenicol were extracted from plasma by a simple one-step protein precipitation with 35% (v/v) perchloric acid.Separation was carried out on a reverse-phase C18 column with a mobile phase of acetonitile-water containing 0.5% (v/v) phosphoric acids (20:80,v/v) at a flow rate of 1.0 mL/min.The column effluent was monitored by UV detection at 300 nm.The column temperature was maintained at 40°C.This method demonstrated good linearity in the range of 0.525-300.0 μg/mL,with correlation coefficients greater than 0.99.The limit of quantification (LOQ) was 0.525 μg/mL in human plasma.Intra-and inter-day precisions were less than 6.63% in terms of relative standard deviation (RSD).The accuracy,when expressed by the bias,ranged from 0.57% to 4.04%.The mean extraction recovery of CTT was higher than 40.94%.The method was found to be precise,accurate,and specific for CTT quantitative analysis,and was successfully applied for a pharmacokinetic study of CTT after a single intravenous dose of 1.0 g of CTT in healthy Chinese subjects.

关 键 词:cefotetan disodium liquid chromatography human plasma PHARMACOKINETICS 

分 类 号:R96[医药卫生—药理学]

 