检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Leimin Chen and Thomas J. Claffey
出 处:《Chinese Medical Journal》1998年第12期38-42,共5页中华医学杂志(英文版)
摘 要:Objective To investigate the effect of horizontal platform supported (HPS) prosthesis on cementless total hip replacement for surgical treatment of arthritis in a long-term follow-up study.Methods Clinical and radiographic follow-up of 65 consecutive primary cementless porous coated HPS total hip replacements, which were implanted in 60 patients between 1982 and 1989, was carried out.Results The 53 hips in 50 patients were evaluated both clinically and radiographically. The average follow-up was 6.8 years (range: 5 to 12 years). According to the Harris hip score, 52 (98%) of the hips had sustained an excellent or good result with an average score of 92. At the time of final assessment, no patient experienced anterior thigh pain. There were two revisions performed early in the series due to technical failures. Radiographically, osteolysis and bone re-modelling were assessed. Conclusion The findings suggest that the clinical and radiographic results after cementless total hip replacement for primary hip arthroplasty may be favourably influenced by the use of the proximal stress loaded HPS femoral component.Objective To investigate the effect of horizontal platform supported (HPS) prosthesis on cementless total hip replacement for surgical treatment of arthritis in a long-term follow-up study.Methods Clinical and radiographic follow-up of 65 consecutive primary cementless porous coated HPS total hip replacements, which were implanted in 60 patients between 1982 and 1989, was carried out.Results The 53 hips in 50 patients were evaluated both clinically and radiographically. The average follow-up was 6.8 years (range: 5 to 12 years). According to the Harris hip score, 52 (98%) of the hips had sustained an excellent or good result with an average score of 92. At the time of final assessment, no patient experienced anterior thigh pain. There were two revisions performed early in the series due to technical failures. Radiographically, osteolysis and bone re-modelling were assessed. Conclusion The findings suggest that the clinical and radiographic results after cementless total hip replacement for primary hip arthroplasty may be favourably influenced by the use of the proximal stress loaded HPS femoral component.
关 键 词:Hip Prosthesis ADULT Aged Arthroplasty Replacement Hip Female Femur Head Necrosis Follow-Up Studies Humans Male Middle Aged Osteoarthritis Hip OSTEOLYSIS
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.70