机构地区:[1]北京医科大学第三医院眼科
出 处:《中国中医眼科杂志》1998年第2期84-87,共4页China Journal of Chinese Ophthalmology
摘 要:目的:观察青光眼眼压调节器植入治疗难治性青光眼的远期临床效果。方法:对接受眼压调节器植入治疗的13例15只眼进行了回顾性总结。结果:在术后平均14.7个月的随访中,仍保留眼压调节器者8只眼,治疗前眼压平均为4.32±0.76kPa,治疗后随访期间眼压为3.02±0.76kPa(t=4.465,P=0.001),摘除眼压调节器者7只眼,治疗前眼压平均为4.45±0.88kPa,治疗后随访期间眼压为3.09±0.80kPa(t=2.882,P=0.014)。结论:青光眼眼压调节器植入是治疗难治性青光眼的方法之一。OBJECTIVE: To investigate long term clinical effect of OptiMed Glaucoma Pressure Regulator (OGPR) implantation in the treatment of refractory glaucoma. METHODS: Data of thirteen patients (15 eyes) with refractory glaucoma were stutied retrosperctively according to clinic examination and follow-up, who were treated with OGPR. RESULTS: The mean period of postoperative follow-up was 147 months. The preoperative mean intraocular pressure (IOP) of 8 eyes kept OGPR was 432±076kPa, in the postoperative follow-up period mean of IOP is 302±076kPa. The preoperative mean IOP of 7 eyes whose OGPR were removed was 445±088kPa and in the postoperative follow-up period mean of IOP was 309±080kPa. CONCLUSIONS: OGPR implantation is one of the methods to treat refractory glaucoma.