检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]辽宁医学院附属第三医院消化科,辽宁锦州120000
出 处:《中国现代医生》2009年第11期68-69,共2页China Modern Doctor
摘 要:目的分析内镜下应用氩离子凝固术(APC)治疗消化道疾病所出现的并发症。方法收集经内镜氩束凝治疗的各种消化道疾病共142例,出现各种并发症11例。其中痉挛性胃痛6例,粘膜下气肿2例,溃疡样病变2例,消化道穿孔1例。结果11例并发症占全部病例7.7%;痉挛性胃痛占4.2%,粘膜下气肿1.4%,溃疡样病变占1.4%,消化道穿孔占0.7%。结论氩离子凝固术治疗消化道相关疾病并发症发生率不高,临床治疗效果佳,是安全可靠的治疗手段。Objective To analyze the complication of the treatment for the diseases of alimentary canal, with endoscopic argon plasma coagulation(APC). Methods 142 cases have been treated with APC during 3 years. Among the 142 patients GI bleeding 32 cases,Polyp or adenoma of alimentary tract 87cases,Verrucosagastritis 27 cases, and 11 cases to been brought about various kinds of complication:6 cases of gastralgia,2 cases of suhmucosa aerocele,2 cases of ulcerous lesion, l cases of GI tract perforation. Results total incidence rate of the complication 7.7%, gastralgia 4.2%, submueosa aerocele 1.4%, ulcerous lesion 1.4%, GI tract perforation 1.4%. Conclusion The therapy of APC for the diseases of alimentary canal is sale and with satisfactory effect. The incidence rate of complication and side-effect is lower.