检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:江先明[1] 杨斌[1] 王铮[1] 黄国富[1] 罗晓阳[2] 张晓晓[1] 周胜[1]
机构地区:[1]中山大学中山眼科中心,广州510060 [2]广东省人民医院眼科
出 处:《中国实用眼科杂志》2009年第5期467-471,共5页Chinese Journal of Practical Ophthalmology
摘 要:目的分析OrbscanⅡ、AS—OCT和Pentacam测量术前检查患者中央角膜厚度(CCT)同超声测厚仪的差异和一致性。方法连续选取行术前检查的屈光不正患者90例(180只眼),对每位患者分别用超声测厚仪、OrbscanⅡ、AS—OCT和Pentacam四种仪器测量其CCT,数据统计分析采用了配对t检验、简单线性相关和Bland—Altman分析。结果超声测厚仪、OrbscanⅡ、AS—OCT和Pentacam测量CCT平均值分别为(542.1±30.4)μm、(541.1±37.1)μm、(530.3±29.3)μm和(544.9±28.7)μm。超声测厚仪和OrbscanⅡ之间的比较没有统计学意义(P〉0.05)。超声测厚仪和AS—OCT、Pentacam之间的差别分别为(11.7±8.9)μm(P〈0.01)、(-2.8±11.0)μm(P〈0.01)。线性相关显示超声测厚仪和OrbscanⅡ、AS—OCT、Pentacam三者间分别存在正相关(P〈0.01)。Bland—Altman分析显示超声测厚仪与OrbscanⅡ、AS—OCT、Pentacam三者间有较好的一致性,95%一致性界限分别为-37.4-+39.3μm、-5.6-+29.1μm、-24.4~+18.8μm。结论对于准分子激光术前患者角膜厚度的测量,三种方法同超声的一致性好,都可用来测量角膜厚度,其中OrbscanⅡ的测量值大小受其声速系数的影响、AS—OCT同超声的一致性最好、Pentacam的测量值同超声最接近。但完全替代使用还须慎重。Objective To analyze the difference and the agreement in central corneal thickness(CCT) measurements between the gold standard method of ultrasound pachymetry and 3 noncontact systems (Orbscan II, AS-OCT, Pentacam)in ametropia eyes before laser refractive surgery.Methods Ninety consecutive patients (180 eyes)who had preoperative examination in Laser Refractive Surgery Center had Orbscan Ⅱ,AS-OCT, Pentacam, and ultrasound pachymetry.Data were analyzed using the paired sample t test, linear regression, and Bland-Altman plots.Results The mean CCT measured by ultrasound,OrbscanlI,Pentacam, and AS-OCT pachymetry were,respectively, (542.1 ± 30.4)μm, (541.1± 37.1)μ m, (530.3_± 29.3)[1 m and (544.9± 28.7)μm.There was no statistically significant difference between ultrasound and OrbscanlI measurements (P〉0.05).Compared with the ultrasound measurement,AS-OCT and Pentacam measurements significantly misestimate corneal thickness by a mean of ( 11.7± 8.9)μ m(P 〈0.01 )and (-2.8± 11.0)μm(P 〈0.01 ),respectively.OrbscanlI, AS-OCT, Pentacam pachymetry showed a high correlation with ultrasound pachymetry. The 95% limits ofagreement (LoA)withultrasoundwere-37.4.-+39.3μm for the Orbscan Ⅱ devieeand-5.6-+29.1 μm for the AS-OCT device and -24.4-+18.8 1.1 μm for the Pentacam device.Conclusions OrbscanlI,AS-OCT and Pentacam pachymetry can be used to measure central corneal thickness.Compared with the ultrasound pachymetry, OrbscanlI pachymetry was effectd by it's AF, AS-OCT pachymetry had the best agreement, Pent,acam pachymetry had the nearest CCT.However it is cautious to use the 4 devices interchangeably.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.134.95.211