超声导向下用自制同轴套针行胆道穿刺──提高操作的安全性和准确性  被引量:2

Sonography Guided Bile Ducts Puncture with Home made Coaxial Fine Needle Introducing Sets to Increase both Security and Accuracy of the Procedure

在线阅读下载全文

作  者:梁惠民[1] 冯敢生[1] 吴汉平[1] 江利[1] 徐才元[1] 

机构地区:[1]同济医科大学附属协和医院放射科

出  处:《临床放射学杂志》1998年第5期304-305,共2页Journal of Clinical Radiology

摘  要:目的:评价用自制同轴细针在B超导向下行胆道穿刺的临床应用结果。材料与方法:使用两种自制的同轴细套针,在B超导向下对11例病人进行了胆道穿刺。结果:穿刺成功率100%,均在1~3针内成功,无并发症,全部穿刺均进入胆道周围分支。Objective: To evaluate the clinical applications of home made coaxial introducing sets guided by US in bile duct puncture.Materials and Methods:US guided punctures were caried out in 11 patients with bile duct obstruction using two kind of renovated coaxial fine needle introducing sets. Results:Selective access to peripheral bile ducts was accomplished with 100% success and within the limits of 1 to 3 punctures, no complication was noticed.Conclusion: The use of home made coaxial fine needle guide by US. Could improve the security and accuracy in bile duct puncture.

关 键 词:胆道穿刺 超声导向 胆道疾病 介入疗法 安全性 

分 类 号:R575.605[医药卫生—消化系统] R446.8[医药卫生—内科学]

 