Triton X-100基体改进剂石墨炉原子吸收法直接测定血镉  被引量:3

Determination of Cd in Blood with GFAAS by Triton X-100 as Matric Modifier

在线阅读下载全文

作  者:易海艳[1,2] 胡建安[1] 

机构地区:[1]中南大学公共卫生学院,湖南长沙410078 [2]湖南省劳动卫生职业病防治所

出  处:《实用预防医学》2009年第5期1570-1571,共2页Practical Preventive Medicine

摘  要:目的建立有机试剂作为基体改进剂测定血中镉的石墨炉原子吸收法。方法利用Triton X-100表面活性剂的性质,将血液进行稀释制成悬浮液直接进样,直接测定血液中镉的含量。结果方法的检出限为0.01μg/L,回收率为96.0%~101.5%,相对标准偏差(RSD)小于6.0%。结论该法样品溶液易于灰化,原子化信号得以改善,基体干扰明显减少,简便易行,适用于大批血样中镉的测定。Objective To develop a method for determination of cadmium in blood with GFAAS. Methods Blood r sample was diluted into suspension by Triton X- 100 solution and then determined by GFAAS. Results The detection limit was 0.01 μg/L, the recovery rate was from 96.0 % to 101.5 %, and the RSD was less than 6.0 %. Conclusions The results show that the samples are easy to incinerate, the atomization signal is improved, and the background is reduced significantly. This method is characterized by convenient procedure, good sensitivity and satisfactory accuracy, which can be used to determine cadmium in blood.

关 键 词:TRITON X-100 基体改进剂 石墨炉原子吸收光谱法 血镉 

分 类 号:R-331[医药卫生]

 