Clinical evaluation of target controlled infusion system for sufentanil administration  被引量:26

Clinical evaluation of target controlled infusion system for sufentanil administration

在线阅读下载全文

作  者:ZHAO Yan ZHANG Li-ping WU Xin-min JIANG Jian-yu DUAN Jing-li HU Yong-fang LI Min LIU Wei SHENG Xiao-yan NI Cheng XU Mao GUO Xiang-yang 

机构地区:[1]Department of Anesthesiology, Peking University Third Hospital, Beijing 100191, China [2]Department of Anesthesiology, Peking University First Hospital, Beijing 100034, China [3]Department of Pharmacy, Peking University Third Hospital, Beijing 100191, China

出  处:《Chinese Medical Journal》2009年第20期2503-2508,共6页中华医学杂志(英文版)

摘  要:Background Sufentanil target controlled infusion (TCI) provides stable analgesia, better hemodynamic control than a bolus injection of intravenous anesthetics, anticipated recovery and improved quality of anesthesia during perioperative period. This study evaluated the accuracy and feasibility of TCI system for sufentanil at high concentrations in Chinese surgical patients. Methods Twelve low risk adult patients undergoing elective surgery under general anesthesia were included in this study. Sufentanil was administered with a specific TCI system incorporating the population pharmacokinetic data of sufentanil previously reported, using a target effect-site concentration of sufentanil 4 or 6 ng/ml. Sufentanil TCI duration was 30 minutes. Frequent arterial blood samples were taken during and up to 24 hours after sufentanil TCI for determination of plasma sufentanil concentrations by liquid chromatography-mass spectrometry/mass spectrometry. The changes of circulatory system function during the procedure, recovery profile and adverse effects were recorded. Measured plasma sufentanil concentrations were compared with the values predicted by the TCI system. The bias (median performance error, MDPE), precision (median absolute performance error, MDAPE) and wobble (variability of performance error) of the sufentanil TCI system were determined. Results All patients had stable cardiovascular variables during induction and maintenance of anesthesia. Time to eye opening and extubation were (5.6±1.7) minutes when TCI set to 4 ng/ml and (7.2±2.3) minutes when set to 6 ng/ml. There was no episode of agitation, muscle rigidity or intraoperative awareness. The bias (MDPE), precision (MDAPE) and wobble of the sufentanil TCI system were -3.7%, 18.9% and 19.6% respectively during TCI, and the MDPE, MDAPE and wobble were -29.1%, 31.7% and 15.0% respectively after TCI (up to 8 hours). Conclusions The TCI system programmed for sufentanil at 4 or 6 ng/ml was considered acceptable for clinical use iBackground Sufentanil target controlled infusion (TCI) provides stable analgesia, better hemodynamic control than a bolus injection of intravenous anesthetics, anticipated recovery and improved quality of anesthesia during perioperative period. This study evaluated the accuracy and feasibility of TCI system for sufentanil at high concentrations in Chinese surgical patients. Methods Twelve low risk adult patients undergoing elective surgery under general anesthesia were included in this study. Sufentanil was administered with a specific TCI system incorporating the population pharmacokinetic data of sufentanil previously reported, using a target effect-site concentration of sufentanil 4 or 6 ng/ml. Sufentanil TCI duration was 30 minutes. Frequent arterial blood samples were taken during and up to 24 hours after sufentanil TCI for determination of plasma sufentanil concentrations by liquid chromatography-mass spectrometry/mass spectrometry. The changes of circulatory system function during the procedure, recovery profile and adverse effects were recorded. Measured plasma sufentanil concentrations were compared with the values predicted by the TCI system. The bias (median performance error, MDPE), precision (median absolute performance error, MDAPE) and wobble (variability of performance error) of the sufentanil TCI system were determined. Results All patients had stable cardiovascular variables during induction and maintenance of anesthesia. Time to eye opening and extubation were (5.6±1.7) minutes when TCI set to 4 ng/ml and (7.2±2.3) minutes when set to 6 ng/ml. There was no episode of agitation, muscle rigidity or intraoperative awareness. The bias (MDPE), precision (MDAPE) and wobble of the sufentanil TCI system were -3.7%, 18.9% and 19.6% respectively during TCI, and the MDPE, MDAPE and wobble were -29.1%, 31.7% and 15.0% respectively after TCI (up to 8 hours). Conclusions The TCI system programmed for sufentanil at 4 or 6 ng/ml was considered acceptable for clinical use i

关 键 词:ANESTHESIA ANALGESIC SUFENTANIL target-controlled infusion tandem mass spectrometry 

分 类 号:R686[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象