硅油填充眼超声生物测量法的临床观察  被引量:4

Clinical results of ultrasound biometry in silicone oil-filled eye

在线阅读下载全文

作  者:刘国军[1] 沈宝莲[2] 仇宜解[1] 于湛[1] 崔虎山[1] 王海存[3] 康维强[3] 刘泳[3] 

机构地区:[1]青岛市海慈医疗集团青岛大学医学院附属海慈医院眼科中心,266033 [2]青岛市海慈医疗集团青岛大学医学院信息中心,266033 [3]青岛市海慈医疗集团青岛大学医学院彩超室,266033

出  处:《中华眼科杂志》2010年第2期113-118,共6页Chinese Journal of Ophthalmology

摘  要:目的探讨硅油填充眼超声生物测量法的临床效果。方法系列病例研究。根据超声测距原理,对相同高度的平衡盐溶液和硅油进行对比研究,计算出其间的测距比例常数(0.674),从而建立硅油填充眼矫正眼轴的测算公式,即公式=ab+0.674×bc(a、b、c分别为角膜顶点、晶状体后极或囊膜中央点、黄斑表面)。然后,采用Vivid7型超声诊断仪对150例(150只眼)硅油填充眼取出硅油前后的眼轴和玻璃体腔前后径进行测量,根据眼轴的长度分为两组,即第1组患者的眼轴长度〈25mm,第2组患者的眼轴长度≥25mm。其中76只眼在硅油取出联合人工晶状体(IOL)植入术前,按Sanders retzlaff kraftT公式计算出IOL度数,将术后实际屈光状态与术前预见屈光状态进行比较。两组患者术前后眼轴长度、玻璃体腔前后径、屈光状态进行比较,采用配对t检验。结果150例(150只眼)硅油填充眼患者术后随访3个月,视网膜病变稳定。生物测量结果:第1组111只眼,硅油取出术前矫正眼轴长度为21.10—24.90mm,平均(22.77±1.00)mm;硅油取出术后眼轴长度21.00~24.70mm,平均(22.76±0.99)mm;两者之间的差异无统计学意义(t=0.518,P〉0.05);111只眼取出硅油前与后玻璃体腔前后径的超声测量值分别为(26.57±2.14)mm和(17.90±1.38)mm,后者与前者的比值为0.67378。第2组39只眼,硅油取出术前矫正眼轴长度为25.00~30.58mm,平均(26.52±1.31)mm;硅油取出术后眼轴长度为25.00-30.59mm,平均(26.53±1.29)mm;两者之间的差异也无统计学意义(t=0.109,P〉0.05);39只眼硅油取出前与后玻璃体腔前后径的超声测量值分别为(32.01±2.90)mm和(21.57±2.04)mm,后者与前者的比值为0.67395。两组76例(76只眼)IOL植入术后患者随访3个月以上,其术后实际屈光Objective To evaluate a method of ultrasound biometry in silicone oil-filled eye and its clinical results. Methods This was a series case study. According to the principle of measuring a distance with ultrasound, we compared the measured distance between a space filed with balanced salt solution and silicone oil at same height, to calculate a conversion factor (0. 674) between them. A formula for corrective axial length in silicone oil-filled eye was established. The formula = ab + 0. 674 × be ( a, b and c standing for the apex of the cornea, the posterior pole of the lens or the center of the capsular membrane and the anterior surface of the macular, respectively). The axial lengths of 150 silicone oil-filled eyes in 150 cases were then measured before and after silicone oil removal with Vivid 7 Dimension ultrasound. According to the axial length, they were divided into two groups, namely group 1 (the length 〈25 mm) and group 2 (the length1〉 25 mm). In 76/150 eyes, before combined silicone oil removal and intraocular lens (IOL) implantation, the SRKT formula was used for intraocular lens calculation; the post-operative actual refraction was compared with the pre-operative predicted refraction and statistics analysis was made. Results The retinal condition of 150 silicone oil-filled eyes in 150 cases after 3 months' follow-up was stable after surgery. The results of the biometry were as follows. In the first group, the mean corrective axial lengths of 111 silicone oil-filled eyes before silicone oil removal was (22.77± 1.00) mm ( ranging from 21.10 to 24. 90 mm) ; the mean axial lengths after silicone oil removal was (22. 76 ± 0. 99) mm ( ranging from 21.00 to 24.70 mm). The difference between them was not statistically significant (t = 0. 518,P 〉 0.05). The vitreous cavity depth before and after silicone oil removal was (26. 57 ±2. 14) mm and( 17. 90± 1.38) mm, respectively. The ratio of the latter to the former was 0. 673 78. In the second group, th

关 键 词:硅油类  超声检查 晶体 人工 人体测量术 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象