Fenton试剂液相催化氧化法净化甲苯气体  被引量:9

Purification of Toluene-containing Gas Stream by Aqueous Oxidation with Fenton Agent

在线阅读下载全文

作  者:莫虹[1] 田森林[1] 蒋蕾[1] 戴春皓[1] 

机构地区:[1]昆明理工大学环境科学与工程学院,昆明650093

出  处:《武汉理工大学学报》2010年第5期116-119,共4页Journal of Wuhan University of Technology

基  金:国家自然科学基金(20607008)

摘  要:证明利用Fenton试剂催化氧化法处理甲苯废气是可行的。研究分析了初始pH值、H2O2浓度、[H2O2]/[Fe^2+]、不同金属离子等因素对甲苯去除率的影响。研究结果表明:最佳实验条件为pH=2.6、H2O2的浓度在0.4-0.5 mol/L、[H2O2]/[Fe^2+]=4、T=50℃;不同金属离子对甲苯的最大去除率为:Fe^2++Fe^3+〉Fe^2+〉Cu^2++Fe^2+〉Fe^3+〉Cu2++Fe^3+〉Cu^2+;穿透时间为:Cu^2++Fe^3+〉Cu^2++Fe^2+〉Fe^2++Fe^3+〉Fe^3+〉Fe^2+=Cu^2+。It was proved to be feasible that the method by aqueous oxidation with Fenton agent can be used to purify the toluene-containing gas stream.The primary factors such as initial solution pH,H2O2 concentration,mole ratio of [H2O2]/,different metal ions which would influence the removal efficiency of toluene,were investigated.The following conclusions were obtained: pH 2.6,H2O2 concentration of 0.4~0.5 mol/L,/ =4,T=50 ℃ were the best experimental conditions;The catalytic capacities of various metal ions to activate H2O2 follow the order: Fe^2++Fe^3+ Fe^2+ Cu^2++Fe^2+ Fev3+ Cu^2++Fe^3+ Cu^2+ ;The order of the penetration time was: Cu^2++Fe^3+ Cu^2++Fe^2+ Fe^2++Fe^3+ Fe3+ Fe^2+ = Cu^2+.

关 键 词:甲苯 FENTON试剂 液相催化氧化 

分 类 号:X131.1[环境科学与工程—环境科学]

 