新型静电场采样器采集流感病毒研究  被引量:5

Study on efficiency of electrostatic sampling devices in collecting influenza virus

在线阅读下载全文

作  者:甄世祺[1,2] 张惠力[2] 周明浩[2] 陈晓东[2] 尹立红[1] 陈连生[2] 要茂盛[3] 

机构地区:[1]东南大学公共卫生学院,江苏南京210009 [2]江苏省疾病预防控制中心,江苏南京210009 [3]北京大学环境与工程学院,北京100871

出  处:《江苏预防医学》2010年第3期1-3,共3页Jiangsu Journal of Preventive Medicine

基  金:江苏省科技计划项目(BS2007069)

摘  要:目的:研究新型静电场采样装置采集空气中流感病毒的效率。方法:通过实验室模拟产生病毒气溶胶,使用新型静电场采样器采集并用QPCR方法检测收集液中病毒的浓度,与原液中病毒浓度比较。结果:静电场采样装置对流感病毒的采样效率可以达到26%。结论:新型的静电场器可以用于采集空气中病毒,并可以通过改进提高采集效率。Objective:To study the sampling efficiency of the electrostatic sampling devices in collecting influenza virus. Methods: The aerosol of influenza virus were collected by electrostatic sampling device , then their concentrations were measured by QPCR. The concentration of sampling by the electrostatic sampler for the aerosol of influenza virus were compared with original liquid. Results: The collective efficiency of electrostatic sampling devices was 26%. Conclusions: Electrostatic sampling devices is effective for collect virus bioaerosol.

关 键 词:新型静电场采样器 流感病毒 定量PCR 