空调冷凝水的分析与再利用  被引量:15

Analysis on Recycling of Air-conditioning Condensed Water

在线阅读下载全文

作  者:张东放[1] 

机构地区:[1]广东建设职业技术学院,广州510440

出  处:《建筑节能》2010年第5期75-77,共3页BUILDING ENERGY EFFICIENCY

摘  要:空调系统在夏季运行时,当冷却器的表面温度低于空气的露点温度时,空气经过冷却器时就会析出冷凝水,通过空调冷凝水水量、水温及水质测试分析,将空调冷凝水再利用到空调冷却水系统,不仅提高制冷装置的制冷系数,而且节约水资源。The condensed water can be separated out from the air through the condenser, if the surface temperature of the condenser is lower than the dew point temperature of the air when the conditioning system operates in summer. Through testing and analyzing the quantity, temperature and quality of air-conditioning condensed water, it would be possible to recycle the condensed water into the condensation system, which will not only improve the refrigeration coefficient in condensation device but also save the water recourse.

关 键 词:空调冷凝水 节水分析 节能分析 再利用 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 