XL-射频皮肤治疗仪消融去除睑黄瘤  被引量:14

Successful eradication of xanthelasma palpebrarum using XL-radiofrequency ablation skin apparatus

在线阅读下载全文

作  者:王兴林[1] 索伟[1] 蒋天裕[1] 何庆华[2] 肖红雨[1] 

机构地区:[1]中国人民解放军总医院理疗科,中国北京市100853 [2]中国人民解放军总医院眼科中心,中国北京市100853

出  处:《国际眼科杂志》2010年第7期1383-1385,共3页International Eye Science

摘  要:目的:研究XL-射频皮肤治疗仪(解放军总医院理疗科研制)消融技术去除睑黄瘤的方法并观察其疗效。方法:采用射频消融治疗40例(73处病变),病变长3~15mm,宽3~10mm,面积6~150(平均44±34)mm2。射频消融电极沿着睑黄瘤病变部位分层达底部,形成保护层。随访观察1~3a。结果:40例(73个病变)1次治愈35例67处病变,4例6处病变1次去除后残留很少部分,2次去除后痊愈,无疤痕。1例2处病变术后7mo复发,2例2处治疗部位轻微的色素脱失。39例痊愈,1例显效。射频消融治疗后眼睑疼痛不明显,次日创面结痂,0.5mo左右脱落。部分病例脱痂后局部皮肤发红,6~10mo消退。XL-射频皮肤治疗仪消融去除睑黄瘤手术操作方便,在手术放大镜下精准性高、视野清晰,手术时不出血、时间短、无烟雾、患者痛苦少、一次性消融电极,术后炎症反应轻、无感染、未用抗生素预防感染,愈合后无肉眼可见的疤痕、复发率低。结论:XL-射频皮肤治疗仪消融去除睑黄瘤是一项精准度易于控制、疗效显著的手术技术,值得临床推荐的新疗法。AIM: Therapeutic methods of XL-radiofrequency abla- tion skin apparatus (invented by department of Phy- siotherapy, Chinese PLA General Hospital) in eradicating xanthelasma palpebrarum are studied and their clinical effects are investigated.METHODS: XL-radiofrequency ablation skin apparatus was performed on 40 cases 73 lesions of xanthelasma palpebrarum with the length of 3-15mm and width of 3- 10mm in an area of 6-150 (average 44 ± 34)mm2 by separat: ing layer and ablation removing methods. The postopera- tive follow-up durations ranged from 1 to 3 years.RESULTS: In 40 patients with 73 lesions, 35 cases 67 lesions were cured successfully by once and 4 cases 6 lesions by twice with well healing, no-scarring with cure in 39 cases and marked result in 1 case. 1 case 2 lesions had a recurrence in postoperation of 7 months, 2 cases 2 lesions had e slight hypopigmentation. The protective crust over lesion was formed next day and fall off half month postoperation. Local en/themia in several cases occurred after the crust fall off and disappeared during 6 to 10 months. XL-radiofrequency ablation skin apparatus offered several advantages, such as easy operation, high accuracy, clear visible field under the operative magnifier, no bleeding, shorter operation time, no smog, little pain, one-off ablation electrode during the procedure, slight inflammation reaction, no infection, no antibiotics following operation, no visible scarring and lower recurrence after healing.CONCLUSION- The efficacy of XL-radiofrequency abla- tion skin apparatus is significantly more evident and safe in eradicating xanthelasma palpebrarum.

关 键 词:射频消融 睑黄瘤 

分 类 号:R777[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象