检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江医科大学附属第二医院眼科中心
出 处:《中国实用眼科杂志》1999年第1期34-36,共3页Chinese Journal of Practical Ophthalmology
摘 要:针对目前临床上常用的SRKⅡ公式在计算人工晶体屈光度时的局限性,对415只后房型人工晶体眼的角膜屈光力、眼轴长度和正视化人工晶体屈光度进行回归分析后,设计出一种不同于传统的线性回归公式的曲线回归公式——二元三次计算公式。结果:二元三次回归公式为一单调递增曲线,呈连续分布,不分区间。利用二元三次回归公式计算的总体标准差小于SRKⅡ公式的总体标准差。Objective:Since some limitaions of SRK Ⅱ formula,the dual cubic curved regressive formula was designed.methods:By means of computer,statistical analysis and regressive treatment of kerato diopter,axial length and emmetropic IOL diopter of 415 pseudophakia was done.Result:The dual cubic regressive formula was a progressively increased curve with continous distribution,and the standard deviation produced by the dual cubic formula was less than the standard deviation produced by SRK Ⅱ formula.conclusion:The dual cubic regressive method could be used to calculate IOL diopter more accurately.