宝安体育场屋盖张拉结构施工环境温度影响分析  被引量:11

Temperature effects during construction of the tension roof structure of Bao'an Stadium

在线阅读下载全文

作  者:郭彦林[1] 王昆[1] 田广宇[1] 张博浩[1] 

机构地区:[1]清华大学土木工程系,北京100084

出  处:《建筑结构》2010年第7期52-55,共4页Building Structure

摘  要:结合一典型模型的理论推导和对深圳市宝安体育场的有限元分析,研究了施工环境温度对车幅式张拉结构成型后索力的影响。为了防止索力偏离设计值过大,从理论上提出了3种消除温度影响的措施,并通过宝安体育场的算例进行了校核。Theoretical derivation for a typical structural model and finite element analysis of Bao'an stadium in Shenzhen were carried out in order to investigate temperature effects on cable force.Obvious deviation of cable force from its design value was not expected,so three measures for correcting deviation of cable force were proposed for Bao'an Stadium,and it will remove the temperature effects mentioned above.These measures were proved to be effective in Bao'an Stadium.

关 键 词:车幅式张拉结构 施工过程 温度影响 宝安体育场 

分 类 号:TU974[建筑科学—建筑技术科学]

 