高速并行采样中时间非均匀性测试与校准方法  被引量:2

An Evaluation and Calibration Method for Sampling Time Uniformity of High-speed Parallel Sampling Systems

在线阅读下载全文

作  者:潘卉青[1] 田书林[1] 叶芃[1] 曾浩[1] 

机构地区:[1]电子科技大学自动化工程学院,四川成都611731

出  处:《计量学报》2010年第4期354-358,共5页Acta Metrologica Sinica

基  金:基金项目:国家自然科学基金(60772145、60827001)

摘  要:并行交替采集系统中,由于各采样通道间时间延迟不一致引入的偏差使得输出采样序列非均匀,严重地降低了系统性能。现有盲估计算法计算量大,无法实现工程应用。通过分析采样样本统计变化趋势,提出了一种计算量更小的采样通道延迟估计算法,并采用分数延时滤波器完成校正,降低了设计难度与成本,系统校正性能和实时性高,适于工程实现。In parallel time-interleaved system, timing mismatch of this structure degrades the performance of the whole ADC system. The blind identification has high complexity, and is not suitable for application. A calibration algorithm utilized statistical properties of signal is proposed, which has small computational demands. The fractional delay filter is adopted to complete timing adjustment, which simplifies the design and decreases the cost. This method has good calibration and high real time characteristics.

关 键 词:计量学 时间交替 数据采集 采样通道间延迟 时域测量 

分 类 号:TB973[一般工业技术—计量学]

 

参考文献: