Research on the response model of microbolometer  

Research on the response model of microbolometer

在线阅读下载全文

作  者:隋修宝 陈钱 顾国华 刘宁 

机构地区:[1]School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology

出  处:《Chinese Physics B》2010年第10期642-651,共10页中国物理B(英文版)

基  金:Project supported by the National Defense Pre-research Fund of China (Grant No. 50405050303);the Natural Science Foundation of Jiangsu Province of China (Grant No. BK2009049)

摘  要:There are certain limitations in the application of uncooled focal plane array (FPA) detector due to the lack of an effective response model which reliably transforms the target temperature to analog output voltage. This paper establishes the response model of microbolometer through researching the detection theory of microbolometer and the heat balance equation under the condition of the pulsed voltage bias. In the establishing process, we simplified the heat balance equation to acquire a simple answer. The experimental data show that, in the temperature dynamic range of 30 K, the biggest tolerance between the model data and the experiment data is 0.2 K; while in the temperature dynamic range of 100 K, it is 1 K. This model can reflect the real response of the microbolometer with only small differences which are acceptable in engineering applications.There are certain limitations in the application of uncooled focal plane array (FPA) detector due to the lack of an effective response model which reliably transforms the target temperature to analog output voltage. This paper establishes the response model of microbolometer through researching the detection theory of microbolometer and the heat balance equation under the condition of the pulsed voltage bias. In the establishing process, we simplified the heat balance equation to acquire a simple answer. The experimental data show that, in the temperature dynamic range of 30 K, the biggest tolerance between the model data and the experiment data is 0.2 K; while in the temperature dynamic range of 100 K, it is 1 K. This model can reflect the real response of the microbolometer with only small differences which are acceptable in engineering applications.

关 键 词:MICROBOLOMETER detection theory response model capacitive transimpedance amplifier 

分 类 号:TN29[电子电信—物理电子学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象