supported by the One Hundred Talents Program of the Chinese Academy of Sciences;the National Natural Science Foundation of China(Grant Nos.61376083 and 61307077);the China Postdoctoral Science Foundation(Grant Nos.2013M530613 and 2015T80080);the Guangxi Key Laboratory of Precision Navigation Technology and Application(Grant Nos.DH201505,DH201510,and DH201511)
We propose a periodic structure as an extra absorption layer(i.e., absorber) based on surface plasmon resonance effects, enhancing dual-band absorption in both middle wavelength infrared(MWIR) and long wavelength ...
supported by the National Natural Science Foundation of China(Grant Nos.61235006 and 61421002)
A method for system-level simulation between microbolometer designing and Read-Out Integrated Circuit(ROIC) was studied. Three-dimensional(3D) structure modeling of the microbolometer was built. Thermal capacity, ther...
funded by the Research Council of Norway(Program:"Bionær")。
It has been long known that thermal imaging may be used to detect stress(e.g.water and nutrient deficiency)in growing crops.Developments in microbolometer thermal cameras,such as the introduction of imaging arrays tha...
Project supported by the National Natural Science Foundation of China(Nos.60806038,61131004,61274076);the National HighTechnology Research and Development Program of China(Nos.2006AA040102,2006AA040106)
This paper introduces a low-cost infrared absorbing structure for an uncooled infrared detector in a standard 0.5 m CMOS technology and post-CMOS process. The infrared absorbing structure can be created by etching the...
Project supported by the National Basic Research Program of China (Grant No. 2011CBA00107);the National High-Technology Research Development Program of China (Grant No. 2011AA010204)
A novel room-temperature microbolometer array chip consisting of an Nb5N6 thin film microbridge and a dipole planar antenna, which is used as a terahertz (THz) detector, is described in this paper. Due to the high-t...
In this paper, vanadium oxide thin film of TCR of -3.5%/K has been deposited by pulsed DC magnetron sputtering method. The property of this VOx has been investigated by X-ray diffractometer (XRD) and atomic force mi...
Project supported by the National Defense Pre-research Fund of China (Grant No. 50405050303);the Natural Science Foundation of Jiangsu Province of China (Grant No. BK2009049)
There are certain limitations in the application of uncooled focal plane array (FPA) detector due to the lack of an effective response model which reliably transforms the target temperature to analog output voltage....