Magnetic suspension hip joint: an ideal design of an artificial joint  被引量:1

Magnetic suspension hip joint: an ideal design of an artificial joint

在线阅读下载全文

作  者:DAI Min NIE Tao 

机构地区:[1]Department of Orthopaedics, First Affiliated Hospital ofNanchang University, Nanchang, Jiangxi 330006, China

出  处:《Chinese Medical Journal》2010年第23期3451-3454,共4页中华医学杂志(英文版)

摘  要:Background Artificial joints present certain problems such as osteal absorption and lysis induced by wear debris which leads to loosening of the prosthesis over a period of time. Here we propose a design of an artificial magnetic suspension joint that was prepared by integrating the medical theories of modern material science, magnetism, and medical physics.Methods According to clinical characteristic of biological and mechanical for hip joint, we designed the appearance and dimensions of magnetic suspension joint and placed neodymium-iron-boron permanent magnets in the prosthesis.As the same time, we performed mechanical and biological experiments using artificial magnetic suspension hip joints models.Results By simulated the human hip structure and the external load, we discovered the artificial magnetic suspension hip joints models had much lesser amount and size of wear debris than the ceramic/ceramic artificial hip joint prosthesis in friction wear tests. The force between the artificial joints with magnetic materials that we have calculated is feasible for application of artificial joint. The design of artificial magnetic suspension hip joints models was plausible technically and safe biologically.Conclusion Artificial magnetic suspension hip joints may effectively reduce the incidence of the loosening of prosthesis over a period of time.Background Artificial joints present certain problems such as osteal absorption and lysis induced by wear debris which leads to loosening of the prosthesis over a period of time. Here we propose a design of an artificial magnetic suspension joint that was prepared by integrating the medical theories of modern material science, magnetism, and medical physics.Methods According to clinical characteristic of biological and mechanical for hip joint, we designed the appearance and dimensions of magnetic suspension joint and placed neodymium-iron-boron permanent magnets in the prosthesis.As the same time, we performed mechanical and biological experiments using artificial magnetic suspension hip joints models.Results By simulated the human hip structure and the external load, we discovered the artificial magnetic suspension hip joints models had much lesser amount and size of wear debris than the ceramic/ceramic artificial hip joint prosthesis in friction wear tests. The force between the artificial joints with magnetic materials that we have calculated is feasible for application of artificial joint. The design of artificial magnetic suspension hip joints models was plausible technically and safe biologically.Conclusion Artificial magnetic suspension hip joints may effectively reduce the incidence of the loosening of prosthesis over a period of time.

关 键 词:artificial joint magnetic suspension aseptic loosening OSTEOLYSIS 

分 类 号:TQ320.52[化学工程—合成树脂塑料工业] TQ174.75

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象