准分子激光原位角膜磨镶术后10年分析  

Ten years outcomes after laser in situ keratomileusis for myopia

在线阅读下载全文

作  者:王跃静[1] 徐新荣[1] 张玉娟[1] 吴静[1] 张传伟[1] 

机构地区:[1]江苏省中医院眼科,江苏南京210029

出  处:《南京医科大学学报(自然科学版)》2010年第12期1760-1763,共4页Journal of Nanjing Medical University(Natural Sciences)

摘  要:目的:评价准分子激光原位角膜磨镶术矫正近视术后10年的远期疗效和安全性。方法:对在本院接受准分子激光原位角膜磨镶术矫正近视术后10年的患者39例77眼进行裸眼视力、屈光度和最佳矫正视力及角膜厚度和Orbscan的检查。被随访眼按屈光度数分为2组:≤-6.0 D组和>6.0 D组,同时采用本院近期手术的近视眼患者的术前检查资料设为对照组。结果:术后10年组裸眼视力≥1.0的低、高度数组分别为63%,42%;<1.0分别为27%,58%;最佳矫正视力≥1.0的分别为98%,72%(P≤0.05)。与术前相比,术后10年Orbscan提供的前、后表面的Diff值及3 mm、5 mm的Irreg及角膜厚度均有统计学差异(P<0.01);术后10年组平均角膜厚度高于理论计算值,说明角膜基质值切削后有一定的增殖。结论:准分子激光原位角膜磨镶术治疗近视远期疗效稳定,手术安全性好。Objective: To evaluate the long-term outcomes and safety of laser in situ keratomilesis(LASIK) for myopia.Methods: 39 cases(77 eyes),who underwent LASIK,were divided into two groups: myopia ≤-6.0 D and 〉-6.0 D.All patients were followed-up for 10 years after surgery.The main parameters for evaulation were predictability,stability,safety and efficacy.Uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),refractions,topography,corneal thickness and postoperative complications were recorded at 10 years.Results: At the 10th year,63% of eyes with myopia ≤-6.0 D and 42% of eyes with myopia〉-6.0 D had 1.0 or better UCVA,27% of eyes with myopia ≤-6.0 D and 58% of eyes with myopia〉-6.0 D had less than 1.0 UCVA.98% of eyes with myopia ≤-6.0 D and 72% of eyes with myopia〉-6.0 D had 1.0 or better BCVA(P 〈 0.05).There were significant differences at values of Diff value on anterior and posterior surface,Irreg at 3 mm and 5 mm zone obtained from Orbscan Ⅱand corneal thickness between pre-and post-operation(P 〈 0.01).Mean corneal thickness at the 10th year postoperatively was higher than attempted residual corneal thickness after ablation,it suggested that the stroma of cornea proliferated.Conclusion:LASIK surgery is safe and has predictable and stable results in refractive and visual outcomes in correcting myopia on long-term follow-up.

关 键 词:近视 准分子激光原位角膜磨镶术 远期疗效 安全性 

分 类 号:R778.11[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象