离子注入对超高分子聚乙烯磨损性能的影响  被引量:5

Effect of ion implantation on the wear-resistance of ultra high molecular weight polyethylene

在线阅读下载全文

作  者:朱福英[1] 陈景升[1] 潘浩昌[1] 曹建清[1] 朱德彰[1] 徐洪杰[1] 蔡青[2] 沈金根[2] 陈黎华[2] 何正瑞[2] 

机构地区:[1]中国科学院上海原子核研究所,上海201800 [2]上海第二医科大学,上海200025

出  处:《核技术》1999年第9期517-520,共4页Nuclear Techniques

基  金:上海科技发展基金!96JC14092

摘  要:用80keV不同剂量的C3H8+、N2+对超高分子聚乙烯样品进行离子注入,通过弹性反冲探测分析表面注入层H含量的变化,对样品表面在离子注入前后的磨损性能进行了测试。实验结果显示,离子注入以后样品表面氢含量减少,磨损性能增强。The surface modification was studied for the ultra high molecular weightpolyethylene (UHMWPE) samples implanted by 80keV N2+ and C3H8+ ions withvarious doses. Elastic recoil detection (ERD) was used to measure the hydrogenprofiles in the samples. The KyowA's DF-PM reciprocating tester was used tomeasure the wear quantity of the samples before and after implantation. The resultsshow that a hydrogen deficient surface layer has formed after implantati0n and thewear-resistance of the samples after implantation has been improved. Themechanism of the UHMWPE surface modification was discussed.

关 键 词:离子注入 聚乙烯 弹性反冲探测 磨损 超高分子 