检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖南省劳动卫生职业病防治所中心实,长沙410007
出 处:《中华劳动卫生职业病杂志》2011年第2期150-151,共2页Chinese Journal of Industrial Hygiene and Occupational Diseases
摘 要:目的建立测定尿中四氢呋喃的顶空固相微萃取一气相色谱法。方法以顶空固相微萃取技术处理尿样,用带氢焰离子化检测器的气相色谱仪测定尿中的四氢呋喃。通过对萃取头类型、萃取时间和温度、解吸温度和时间等影响萃取效率的因素的研究,获得了优化的试验条件。结果在优化条件下,方法的线性较好,样品的加标回收率为93.0%~100.8%,相对标准偏差为0.96%~3.85%,检出限可以达到0.5μg/L。结论该方法适用于尿中四氢呋喃的测定。Objective Headspace solid-phase microextraction (HS-SPME) was used pre-concentration procedure for the determination of tetrahydrofuran in urine by gas chromatography with hydrogen flame detector. Methods Several parameters controlling SPME was studied and optimised: SPME fiber, extraction time and extraction temperature, desorption time and desorption temperature. Results Under optimal conditions, the correlation coefficient was 0.9998 and good recoveries (range from 93.0%-100.8%) were achieved, the detection limit was 0.5μg/L. Conclusion The method can be applied to the determination of trace amount of tetrahydrofuran in urine.