检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中南大学湘雅二医院眼科罗知卫,现在湖南省博雅眼科医院,湖南长沙410011
出 处:《中国实用眼科杂志》2011年第3期221-224,共4页Chinese Journal of Practical Ophthalmology
摘 要:目的比较正常人和不同程度青光眼患者GDxVCC系统检测RNFL参数的不同,评价GDx各参数的敏感性、特异性,探讨GDxVCC系统检测视网膜神经纤维层在青光眼早期诊断中的价值。方法对35例(35只眼)原发性开角型青光眼、33例(33只眼)慢性闭角型青光眼、27例(27只眼)急性闭角型青光眼以及年龄相匹配的36人(36只眼)正常人进行GDxVCC系统和静态视野检查。GDxVCC系统检查,视盘周围视网膜神经纤维层(retinalnervefiberlayer,RNFL)任一参数与系统内所附中国正常人数据库对比概率〈5%或NFI〉30或视网膜神经纤维标准偏差图上连续有10个超级像素概率〈5%定义为具有青光眼性视网膜神经纤维层结构损害,并判断为青光眼。结果22只正常眼被判断为非青光眼(61.1%),82只青光眼被判断为青光眼(86.3%),RNFL参数椭圆平均值、上方平均值、下方平均值、TSNIT标准偏差、神经纤维指数,标准偏差图诊断青光眼的敏感性分别为48.4%、56.8%、48.4%、50.5%、62.1%,特异性分别为97.2%、100%、97.2%、94.4%、97.2%、61.1%。GDxVCC系统诊断早期、中期、晚期青光眼的敏感性分别为77.36%、95.83%、100%。结论GDxVCC系统诊断早期青光眼的敏感性和特异性均高,而且RNFL参数中神经纤维指数的敏感性最高。Objective To evaluate the usefulness of the scanning laser polarimeter with variable corneal compensation (GDxVCC) for glaucoma detection in a Chinese population, and to investigate the retinal nerve fiber layer (RNFL) thickness difference between normal subjects and glaucoma patients. Methods Thirty-six eyes of 36 normal subjects, 33 eyes of 33 primary chronic angle-closure glaucoma patients, 27 eyes of 27 primary acute angle-closure glaucoma and 35 eyes of 35 primary open-angle glaucoma patients were studied. The glaucoma patients were age-matched with the normal. The thickness of retinal nerve fiber layer was measured with GDxVCC. An eye was diagnosed as glaucoma, if one of the parameters showed P 〈0.05 on the results of the examination reports including four TSNIT parameters (the average of TSNIT, superior, inferi- or, and TSNIT Std. Dev.), nerve fiber indicator (NFI)〉30, and at least 10 consecutive defects of superpels showed in deviation map (P 〈0.05). Results Of 22 normal eyes (61.1%) were diagnosed as non-glaucoma and 82 glaucomatous eyes (86.3%) were diagnosed as glaucoma by GDxVCC. Sensitivity of the average of TSNIT, superior, inferior, TSNIT Std. Dev., NFI and the deviation map were 48.4%, 56.8%, 48.4%, 50.5%, 62.1% respectively and specificity were 97.2%, 100%, 97.2%, 94.4%, 97.2% and 61.1% respectively. Sensitivity of detection early, moderate and progression glaucoma by GDxVCC were 77.36%, 95.83%, 100% respectively. Conclusions GDxVCC is a valuable technology to detect retinal nerve fiber layer defect in early glaucoma. It is shown that ttie NFI has highest sensitivity.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112