检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘湘生[1] 蔡绍勤[1] 安平[1] 伍星[1] 陈家英[1] 张安定[1]
出 处:《分析化学》1999年第7期782-785,共4页Chinese Journal of Analytical Chemistry
摘 要:报道了高纯氧化钇中30种痕量稀土和非稀土杂质元素的电感耦合等离子体质谱测定方法.考察了谱干扰及基体效应,采用Ga内标能较好地补偿基体钇的影响.方法检出限为0.013~4.1μg/L.方法简便、快速、灵敏.The method of inductively coupled plasma-mass spectrometry for determination of impurities of 30 trace rare earth and non-rare earth elements in high purity ytterbium oxide was studied. The spectral interferences and matrix effect on the method were discussed. The matrix effect of Y could effectively beeliminated by using Ga as an internal standard. The detection limits are 0.013-4.1 μg/L. This method is simple, rapid and sensitive.