AccuMaP多焦视觉诱发电位客观视野检查在黄斑疾病视功能检测中的应用  

Application of AccuMap multifocal visual evoked potential on visual function in macular diseases

在线阅读下载全文

作  者:姜利斌[1] 谢君[1] 焦旋[1] 周海英[1] 

机构地区:[1]首都医科大学附属北京同仁医院北京同仁眼科中心北京市眼科学与视觉科学重点实验室,100730

出  处:《中华眼底病杂志》2011年第2期136-139,共4页Chinese Journal of Ocular Fundus Diseases

摘  要:目的探讨AccuMap多焦视觉诱发电位(mfVEP)客观视野检查在黄斑疾病视功能检测中的应用价值。方法临床确诊为黄斑疾病的37例患者46只眼纳入研究。采用AccuMapmfVEP客观视野计检测患者半径为2.0°、5.5°、10.0°、15.5°和24.0°中心视野的平均反应振幅值。应用概率灰度图和系统自动计算出的AccuMap视野损伤严重程度指数(ASI)表示视野区域缺失情况。同时,采用MP-1微视野计检测患者半径为2.0°、4.0°、6.0°、8.0°和10.0°中心视野的平均光敏感度(MS)和半径为10.0。中心视野的平均缺失敏感度(MD)。对比分析患者最小视角对数(10gMAR)最佳矫正视力(BCVA)、平均反应振幅、MS、ASI及MD之间的相关性。结果AccuMapmfVEP客观视野计检测显示,46只患眼中43只眼ASI异常,且概率灰度图上有明确的视野缺失,占93.45%;3只眼ASI正常,且概率灰度图上无视野缺失,占6.55%。半径为2.0°5.5°10.0°、15.5°和24.0°中心视野的平均反应振幅值分别为(120.78±52.91)、(134.31±54.67)、(149.99±52.42)、(156.69±48.30)和(157.54±45.07)nV;ASI值平均为74.26±52.43。MP-1微视野计检测显示,半径为2.0°、4.0°、6.0°、8.0°和10.0°中心视野的MS值分别为(10.97±5.91)、(12.71±5.13)、(13.71±4.53)、(14.23±4.18)、(14.48±3.86)dB;半径为10.0°中心视野的MD值为(4.49±3.07)dB。ASI、各半径中心视野的平均反应振幅与患眼logMARBCVA间均存在明显相关性(P〈0.06)。半径为2.0°5.5°10.0°中心视野的平均反应振幅与半径为2.0°、6.0°和10.0°中心视野的MS呈明显正相关(r=0.477,0.432,0.433;P=0.001,0.003,0.003)。ASI与半径为10.0°中心视野的MD呈明显正相关(r=0.729,P=0.000)。结论AccuMapmfVEP客观视野检查能客观Objective To evaluate the value of AccuMap multifocal visual evoked potential (mfVEP) objective perimetry in measuring visual function of macular diseases. Methods Forty-six eyes (37 patients) with macular diseases were studied. The mean mfVEP amplitudes of central visual field within radius 2.0°, 5.5°, 10.0°, 15.5° and 24.0° were measured by AecuMap mfVEP objective perimetry. Automatically calculated AccuMap severity index (ASI) represented the visual field defects. Meanwhile, the mean sensitivity (MS) of central visual field within radius 2.0°, 4.0°, 6.0°, 8.0° and 10.0° and mean defect (MD) of central visual field within radius 10.0° were assessed by MP-1 microperimeter. The correlations among those parameters including logMAR visual acuity, mean mfVEP amplitudes, MS, ASI and MD were analyzed. Results Among 46 affected eyes, AccuMap mfVEP objective perimetry showed abnormal ASI with visual field defects in 43 eyes (93.45°), normal ASI without visual field defects in three eyes (6.55°). The mean mfVEP amplitudes value of the central visual field within radius of 2.0°, 5.5°, 10.0°, 15.5°and 24.0° were (120.78°52.91), (134.31±54.67), (149.99±52.42), (156.69±48.30), (157.54±45.07) nV respectively. The mean ASI value was 74. 26±52. 43. MP-1 showed that the MS values of central visual field within radius 2.0°, 4.0°, 6.0°, 8.0° and 10.0° were (10.97±5.91), (12.71± 5.13), (13. 714±4.53), (14.23±4.18), (14.48±3.86) dB respectively. The MD value of central visual field within radius 10° was 4.49±3.07. There was a significant correlation among ASI, the mean mfVEP amplitudes of central visual field with every radius and IogMAR best corrected visual acuity (P〈0.05). The mean mfVEP amplitudes of central visual field within radius 2.0°, 5.5°, 10.0° were positively correlated with the MS of central visual field within radius 2.0°, 6.0°, 10.0° (r=0. 477, O. 432, 0. 433; P°0. 001, 0. 003, 0. 003). Furthermore

关 键 词:视网膜疾病/诊断 视野检查法/方法 诱发电位 视觉 黄斑/病理学 

分 类 号:R775[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象