出  处:《医学信息(中旬刊)》2011年第5期1974-1976,共3页Medical Information Operations Sciences Fascicule

摘  要:目的:探讨金属钛夹在高频电凝电切息肉及EMR术中的使用价值。方法:对于长蒂的息肉先用钛夹钳夹蒂根部后再加用高频电凝电切息肉,而对于广基的息肉则先行高频电凝电切后再用钛夹闭残端;在EMR术后使用钛夹修复创面。结果:225例共256处病灶,成功使用钛夹钳夹249处,成功率为97.3%。所有病例术中未见渗血、术后未见出血及穿孔等并发症。结论:应用金属钛夹预防高频电凝电切息肉和EMR术出血、穿孔等并发症,具有简便、安全性高、疗效好的优点。Objective :To discuss the application of titanium folder in endoscopic hemoclip combined with electrocogulation and electroresection in treating polyps or Endoscopic mucosal resection. Methods:The long, pedunculatede polyps were treated with dipping folder titanium the root of pedunculatc first and then using high - frequency electrocoagulafion and electreresection. But for the broad based polyps were excised with high -frequency electrosection before nipping with Titanium Folder; folder titanium were used clipping wound after the EMR treatment. Results:There are 256 focus of infection in 225 patients,249 cases of polyps were successful by titanium fold, and the success rates can reach 97.3 %. No case emergence of bleeding and perforation during intraoperative or postoperation. Conclusion :Titanium folder can be to stop bleeding and perforation in high -frequency electrocoagulation and electroresection in treating gastrointestintestinal polyps or Endoscopic mucosal resection, so the titanium folder is a simple, high safe, and effective method.

关 键 词:电切 EMR 钛夹 胃肠道息肉 

分 类 号:R735[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象