超声造影对≤4 cm肾脏良恶性病变的诊断价值  被引量:13

The Value of Contrast-Enhanced Ultrasound in the Diagnosis of Renal Tumors Equal to or Smaller than 4 cm

在线阅读下载全文

作  者:李春香[1] 姚欣[1] 李秀英[1] 徐勇[1] 杨庆[1] 叶兆祥[1] 

机构地区:[1]天津医科大学附属肿瘤医院泌尿肿瘤科 天津市肿瘤防治重点实验室,天津市300060

出  处:《中国肿瘤临床》2011年第9期520-523,共4页Chinese Journal of Clinical Oncology

摘  要:目的:探讨超声造影对≤4cm肾脏良恶性病变诊断价值,提高小肾肿瘤的诊断和治疗水平。方法:回顾性分析了2007年6月至2009年10月间天津医科大学附属肿瘤医院收治的72例≤4 cm肾肿瘤住院患者超声造影(CEUS)、增强CT(CECT)的影像学特征,比较CEUS和CECT对≤4 cm肾肿瘤判断情况,比较超声造影对≤4 cm肾脏良恶性病变的增强方式,以探讨超声造影对小肾肿瘤的诊断价值。结果:超声造影将4例肾良性肿瘤误诊为肾癌,漏诊1例肾癌病例,5例不确诊;CECT将5例肾良性肿瘤误诊为肾癌,同样漏诊1例肾癌病例,14例不确诊。超声造影诊断的敏感性、特异性、准确性、阳性预测值、阴性预测值分别为93.10%、71.43%、88.89%、93.10%、71.43%,增强CT诊断的敏感性、特异性、准确性、阳性预测值、阴性预测值分别为81.03%、64.29%、77.78%、90.38%、45.00%。CEUS和CECT对≤4cm肾脏良恶性病变诊断结果比较,差异有统计学意义(P<0.05)。超声造影增强方式比较58例肾恶性肿瘤中19例表现为快进快出,31例表现为快进慢出,3例表现为同进同出,5例表现为慢进慢出;14例肾良性肿瘤中1例表现为快进快出,3例表现为快进慢出,4例表现为同进同出,6例表现为慢进慢出,差异有统计学意义(P<0.05)。结论:CEUS可对肿瘤内微血管形态进行描述且具有特殊的增强方式,提高了诊断的敏感性、特异性、准确性、阳性预测值、阴性预测值,减少了诊断的不确定性,与CECT对≤4 cm肾脏良恶性病变判断比较,超声造影优于增强CT,为我们临床医生选择手术方式提供更加可靠的诊断依据。Objective: To investigate the value of contrast-enhanced ultrasound in the diagnosis of small renal tumors smaller than 4 cm, and to improve the diagnostic and treatment level of benign and malignant tumors of the kidney. Methods: The imaging features of contrast-enhanced ultrasound ( CEUS ) and contrast-enhanced CT ( CECT ) in 72 patients with small renal tumor who were treated in Tianjin Medical University Cancer Institute and Hospital between June 2007 and October 2009 were reviewed. The diagnostic results of CEUS and CECT, as well as the enhancement patterns of CEUS for the malignant and benign renal tumors were compared. The diagnostic value of CEUS for small renal tumors ~〈 4 cm was evaluated. Results: Four benign renal tumor cases were misdiagnosed as renal cancer by CEUS, one renal cancer case was missed by CEUS, and CEUS failed to obtain the final diagnosis for 5 cases. Five benign renal tumor cases were misdiagnosed as renal cancer by CECT, one renal cancer was missed by CECT, and CECT failed to provide final diagnosis for 14 cases. The overall diagnostic sensitivity, specificity, accuracy, the positive and negative predic- tive value of CEUS were 93.10%, 71.43%, 88.89%, 93.10%, and 71.43%, respectively. Those of CECT were 81.03%, 64.29%, 77.78%, 90.38%, and 45.00%, respectively. Enhancement patterns of CEUS were shown by fast in and fast out in 19 cases, fast in and slowly out in 31 cases, synchronously in and out in 3 cases, and slowly in and slowly out in 5 cases. Of the 14 cases with benign tumor of the kidney, enhancement patterns of CEUS in small benign renal tumors were shown by fast in and fast out in one case, fast in and slowly out in 3 cases, synchronously in and out in 4 cases, and slowly in and slowly out in 6 cases. There was statistical significance among them ( P 〈 0.05 ). Conclusion: CEUS is a special mode of enhancement which can be used to delineate the capillary vessels in the tumor and has higher sensitivity, specificity, accuracy, and the positive and negati

关 键 词:肾肿瘤 超声造影 增强CT 诊断 

分 类 号:R737.11[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象