20G与23G玻璃体切割术临床应用比较  被引量:2

The comparison of clinical application in 20G self-sealing sclerotomy versus 23G pars plana vitrectomy

在线阅读下载全文

作  者:张欣[1] 王卓实[1] 王海波[1] 卢山[1] 何伟[1] 

机构地区:[1]沈阳何氏眼科医院,沈阳110034

出  处:《中国实用眼科杂志》2011年第5期471-472,共2页Chinese Journal of Practical Ophthalmology

摘  要:目的 比较20G自闭式巩膜隧道切口玻璃体切割手术与23G玻璃体切割手术治疗黄斑前膜的临床疗效.方法 随机选取21(21只眼)例黄斑前膜患者,10例(10只眼)行20G自闭式巩膜隧道切口玻璃体切割手术,11(11只眼)例行23G玻璃体切割手术.结果 20G自闭式巩膜隧道切口玻璃体切割手术组切口自行闭合率为93.3%,23G玻璃体切割手术组切口自行闭合率为100%,但两组差异无统计学意义(P〉0.05).结论 选取合适病例使用20G自闭式巩膜隧道切口玻璃体切割手术,也可以实现切口无需缝合,且操作简捷、术后反应轻、恢复快,无需增加额外操作设备,具备与23G相似的优点,在无条件实施23G玻璃体切割手术时,是理想的替代术式.Objective To compare the efficacy of 20 Gauge three-channel self-sealing sclerotomy pars plana vitrectomy and sutureless 23Gauge pars plana vitrectomy in macula hole surgery. Methods Twenty-one patients were divided into group A and B. Three-channel self-sealing sclerotomy and 23 Gauge pars plana vitrectomy were performed on patients in group A and B respectively. Results The closure rate of sclerotomies was 93.3% in group A; compared to 100% in group B. No significant difference was found between two groups(P 〉0.05). Conclusions Sutureless surgery can be performed by three-channel self-sealing sclerotomy 20G vitrectomy for appropriate cases with less complication, better recovery and no extra instrument. It might be an alternative substitute for 23Gauge pars plana vitrectomy.

关 键 词:巩膜隧道切口 玻璃体切割 

分 类 号:R779.6[医药卫生—眼科]

 