铁-水体系电位-pH图与氧化性水工况的腐蚀控制  被引量:9

Corrosion Control of Oxidative Water Condition and Potential-pH Chart of Ferrum-Water System

在线阅读下载全文

作  者:谢学军[1] 王浩[1] 邹品果[1] 潘玲[1] 

机构地区:[1]武汉大学动力与机械学院,湖北武汉430072

出  处:《华北电力技术》2011年第5期23-25,共3页North China Electric Power

摘  要:目前超临界直流炉大都采用氧化性水工况,要求给水中铁的含量小于10μg/L。为使超临界直流炉采用的氧化性水工况的腐蚀控制与铁-水体系的电位-pH图统一,不能再以10-6mol/L(即56μg/L)作为钢铁腐蚀与否的界限,而必须以10-6.75mol/L(即10μg/L)作为腐蚀发生与否的界限,绘制铁-水体系的简化电位-pH平衡图时必须在平衡计算中将离子浓度均取10-6.75mol/L(即10μg/L)。The super-critical once through boiler adopts oxidative water condition presently,and it is required that the ferrum ion content in the supplied water should be lower than 10 μg/L.To unify the corrosion controlling of the oxidative water condition and the potential-pH chart of the ferrum-water system,it is considered that 10-6.75mol/L(namely 10 μg/L)is more reasonable than 10-6mol/L(namely 56 μg/L)to be the limit to judge the corrosion.At the same time,the potential-pH chart of ferrum-water system is drawn which ion content is chosen as 10-6.75mol/L(namely 10 μg/L)in the balance calculation.

关 键 词:氧化性水工况 铁-水体系 电位-PH图 

分 类 号:TM621.8[电气工程—电力系统及自动化]

 