基于结霜试验的冷藏室回风口优化分析  被引量:1

Analysis of Refrigerator Return Air Inlet Optimum Based on Frost Experiment

在线阅读下载全文

作  者:常见虎[1] 周小天 胡哲[1] 

机构地区:[1]海信容声(广东)冰箱有限公司,广东佛山528303

出  处:《顺德职业技术学院学报》2011年第3期10-12,共3页Journal of Shunde Polytechnic

摘  要:对一个典型风冷冰箱的蒸发器在不同冷藏室回风口下进行了结霜工况的实验研究,包括回风口大小、回风口位置、回风口形状等对蒸发器结霜的影响,通过分析给出了回风口设计的依据。结果表明:不同的回风口对结霜的影响差别较大;相对于蒸发器,冷藏室回风口的大小要适度,并且以对称为佳。In this paper,the evaporator of a typical frost-free refrigerator with different return air inlets in the fresh storage compartment was studied under frosting condition.The experiment aimed to find the impact of the size and location and shape of the return air inlet on frost of the evaporator and to provide support for the design of the return air inlet.The results showed that: the different return air inlets had vastly different impact on frost;in contrast to the evaporator,the size of the return air inlet in the fresh food storage compartment should be appropriate and,preferably,symmetric.

关 键 词:回风口 冷藏室 蒸发器 结霜 

分 类 号:TM925.21[电气工程—电力电子与电力传动] TM925.03

 