检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Hong-Xia Zhao Hui Mu Yan-Hong Bai Hu Yu Ying-Mei Hu
机构地区:[1]Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
出 处:《Journal of Pharmaceutical Analysis》2011年第3期208-212,共5页药物分析学报(英文版)
基 金:supported by the Natural Science Foundation of Shaanxi Province (no.2009jm4002-1)
摘 要:A rapid method has been developed based on the sample preparation procedure named as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), combined with reversed-phase high performance liquid chromatography with fluorescence detector and C18 column after precolumn derivatization using o-phthalaldehyde and 2-mercaptoethanol to determine dopamine in porcine muscle. Methanol and deionized water (0.1% acetic acid, v/v) with a ratio of 60:40 was used as mobile phase. The flow rate was 0.8 mL/min and dopamine was eluted within 15 min. The linearity range was 0.003-8 μg/mL with r=0.9992. The detection limit for dopamine was 4 μg/kg and the quantification limit was 9 μg/kg. Recovery studies were carried out at 0.1, 0.5 and 1.0 mg/kg fortification levels and the average recoveries obtained ranged from 90.4% to 98.2% with relative standard deviations between 3.5% and 8.1%. The method was found to be suitable for detection of dopamine in animal product tissues at the maximum residue level.A rapid method has been developed based on the sample preparation procedure named as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), combined with reversed-phase high performance liquid chromatography with fluorescence detector and C18 column after precolumn derivatization using o-phthalaldehyde and 2-mercaptoethanol to determine dopamine in porcine muscle. Methanol and deionized water (0.1% acetic acid, v/v) with a ratio of 60:40 was used as mobile phase. The flow rate was 0.8 mL/min and dopamine was eluted within 15 min. The linearity range was 0.003-8 μg/mL with r=0.9992. The detection limit for dopamine was 4 μg/kg and the quantification limit was 9 μg/kg. Recovery studies were carried out at 0.1, 0.5 and 1.0 mg/kg fortification levels and the average recoveries obtained ranged from 90.4% to 98.2% with relative standard deviations between 3.5% and 8.1%. The method was found to be suitable for detection of dopamine in animal product tissues at the maximum residue level.
关 键 词:Liquid chromatography DOPAMINE O-PHTHALALDEHYDE QUECHERS
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145