AcrysofToric人工晶状体矫正角膜散光的临床研究  被引量:1

Clinical study of Acrysof Toric intraocular lens implantation for corneal astigmatism correction

在线阅读下载全文

作  者:周衍文[1] 史庆成[1] 冯宇宁[1] 初玲[1] 

机构地区:[1]沈阳爱尔眼视光医院,沈阳110003

出  处:《中国实用眼科杂志》2011年第11期1136-1138,共3页Chinese Journal of Practical Ophthalmology

摘  要:目的评价AcrysofToric复曲面人工晶状体在白内障手术中矫正角膜源性散光的临床效果及其旋转稳定性。方法随机选取2009年6月至2010年5月行白内障手术的患者,接受白内障超声乳化吸出联合AcrysofToricIOL(sN60TT)植入术的35例(37只眼)做为实验组,其中T3(柱镜为1.50D)17只眼,T4(柱镜为2.25D)10只眼,T5(柱镜为3.00D)10只眼。随机选取同期接受白内障超声乳化吸出联合AcrysofNaturalIOL(SN60AT)植入术的30例(35只眼)做为对照组。全部手术均采用角膜屈光力陡峭子午线透明角膜切口。观察术后3个月术眼裸眼视力(uncorrectedvisualacuity,UCVA)及最佳矫正视力(bestcorrectedvisualacuity,BCVA)、术后术眼角膜散光及预期与实际残余散光、IOL旋转度数。结果术后3个月实验组UCVA为0.65±O.23,对照组为0.55±0.30,两组差异有统计学意义(t=9.526,P〈O.01),实验组BCVA为0.81±0.17,对照组为0.79±0.29,两组差异无统计学意义(t=0.392,P〉0.05)。术后残余散光实验组为(0.55±O.17)D,对照组为(1.89±0.35)D,差异有统计学意义(t=4.215,P〈0.01)。实验组IOL轴旋转平均为(2.5-4-1.7)。,有34只眼(91.9%)的旋转小于5°。结论术后3个月观察表明植入AcrysofToricIOL可以有效且稳定地矫正白内障患者术前存在的角膜散光。Objective To evaluate the result of TORIC intraocular lens (IOL) implantation in correcting corneal astigmatism and the rotation stability in cataract surgery. Method Randomized group 1 (37 eyes) fi'om June 2009 to May 2010 and group 2 (35 eyes) in the same period underwent similar phacoemulsification procedure. Group 1 were combined with Acrysof Toric IOL (SN60TT) implantation of T3 (17 eyes), T4 (10 eyes) and T5 (10 eyes). Group 2 with preoperative corneal astigmatism more than 1.00 diopter (D) were combined with Acrysof Nat- ural IOL (SN60AT) and incision on steep axis. Patients were followed up for 3 months, the uncorrected visual acu- ity (UCVA), best corrected visual acuity (BCVA), residual cylinders, and TORIC IOL axis was measured. Result Three months after operation, the UCVA of all eyes in Group 1 were 0.65±0.23; and were 0.55±0.30 in Group 2, it was statistically significant (t =9.526, P 〈0.01). The BCVA in Group 1 were 0.81±0.17, and were 0.79± 0.29 in Group 2, there was no difference between two groups in BCVA (t =0.392, P 〉0.05). The mean residual astigmatism after surgery in Group 1 was (0.55+ 0.17)D, and was (1.89± 0.35)D in Group 2, there was significant difference between two groups. The mean axis rotation of TORIC IOL was (2.5±1.7) degree in group 1, and less than 5 degrees in 91.9%of eyes. Conclusions The SN60TT TORIC IOL show good effectiveness and stability in correcting pre-existing astigmatism in cataract patients.

关 键 词:白内障 散光 TORIC人工晶状体 

分 类 号:R776.1[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象