膜式水冷壁传热边界条件反演  被引量:7

Estimation of Thermal Boundary Conditions of the Membrane Water Wall

在线阅读下载全文

作  者:蒋文萍[1] 王广军[1] 严飞[1] 陈红[1] 

机构地区:[1]低品位能源利用技术及系统教育部重点实验室(重庆大学),重庆市沙坪坝区400044

出  处:《中国电机工程学报》2012年第5期93-98,共6页Proceedings of the CSEE

基  金:国家自然科学基金项目(51176211)~~

摘  要:膜式水冷壁传热边界条件对现代电站锅炉安全运行有重要影响。针对其难以直接测量的现状,采用共轭梯度法对膜式水冷壁的传热边界条件进行了反演,并讨论了测点数目、待反演参数的初始猜测值及测量误差对反演结果及向火侧金属外壁温度分布的影响。结果表明:增加测点数可提高反演精度,而3个测点即可达到较高精度;反演结果对初值有一定的依赖性;在一定的测量误差范围内,共轭梯度法仍能够得到较满意的结果。The thermal boundary conditions of membrane water wall are of great influence on the safe operation of modern power plant boilers.For its difficulty of direct measurement,the thermal boundary conditions of membrane water wall was inversed using conjugate gradient method,also the influences of the numbers of measured points,the initial guesses of inverse parameters and the measured errors on the accuracy of inverse solutions and the temperature distribution at fire side part of the tube were discussed.The results show that,the accuracy of inverse solutions can be improved by increasing the numbers of measured points,while three measured points can achieve a high accuracy.The initial guesses of inverse parameters are dependent on the accuracy of inverse solutions in some degree.When the measured temperatures contain some error,the satisfactory results can also be obtained with the method.

关 键 词:膜式水冷壁 传热边界条件 共轭梯度法 传热反问题 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象