LC/MS/MS方法筛查新生儿苯丙酮尿症  被引量:8

Newborn Screening of Phenylketonuria by LC/MS/MS

在线阅读下载全文

作  者:曲峻[1] 吴筑平[1] 罗国安[1] 刘密新[1] 杨成对[1] 

机构地区:[1]清华大学分析中心,北京100084

出  处:《高等学校化学学报》2000年第2期210-212,共3页Chemical Journal of Chinese Universities

基  金:国家自然科学基金!(批准号 :296350220)重点资助项目

摘  要:The application of MS/MS in newborn screening is one of the most important branches of MS/MSs current clinical applications. In this paper, we firstly reported a new method of newborn screening for Phenylketonuria(PKU) by coupling LC with MS/MS, which was relatively cheap, fast, sensitive, and accurate. In this method, only a few steps of sample preparation were required and no isotopically labeled internal standard was required. Phe and Tyr were extracted from dry blood spots with 0.1 mol/L HCl-methanol and reacted with 2.8 mol/L HCl-butanol at 68 ℃ for 35 min. MS/MS was used as a detector for LC and multi reactions monitoring (MRM) scan mode was employed to determine phenylalanine and tyrosine in blood samples. Among the product ions of Phe and Tyr butyl esters, [M+H-102]+ was the most abundant in intensity and unique to α-amino acids, therefore the precursor-daughter ion pairs of m/z 222—120 and m/z 238—136 were selected as MRM ion pairs. The contents of these two amino acids in blood samples were determined by calculating the areas of their ionic flow peaks. Finally, the molar ratios of Phe to Tyr in blood samples were calculated as the basis of PKU diagnosis. The curve for Phe showed excellent linearity over the concentration range of 241 152 μmol/L(r2=0999). As to Tyr, the range of linearity was 221 056 μmol/L(r2=0998). The average analytical recoveries of added Phe and Tyr from blood were 98% and 96%, respectively. The limits of detection for Phe and Tyr were respectively 0.5 pg and 2.0 pg , which were 103 times lower than that of reported MS/MS method. About 40 blood samples were analyzed by this method, and the results proved that this method could successfully discriminate between normal infants and PKU positive ones. Each samples analysis time was about 4 minutes; therefore it was capable for large-scale screening.The application of MS/MS in newborn screening is one of the most important branches of MS/MSs current clinical applications. In this paper, we firstly reported a new method of newborn screening for Phenylketonuria(PKU) by coupling LC with MS/MS, which was relatively cheap, fast, sensitive, and accurate. In this method, only a few steps of sample preparation were required and no isotopically labeled internal standard was required. Phe and Tyr were extracted from dry blood spots with 0.1 mol/L HCl-methanol and reacted with 2.8 mol/L HCl-butanol at 68 ℃ for 35 min. MS/MS was used as a detector for LC and multi reactions monitoring (MRM) scan mode was employed to determine phenylalanine and tyrosine in blood samples. Among the product ions of Phe and Tyr butyl esters, [M+H-102]+ was the most abundant in intensity and unique to α-amino acids, therefore the precursor-daughter ion pairs of m/z 222—120 and m/z 238—136 were selected as MRM ion pairs. The contents of these two amino acids in blood samples were determined by calculating the areas of their ionic flow peaks. Finally, the molar ratios of Phe to Tyr in blood samples were calculated as the basis of PKU diagnosis. The curve for Phe showed excellent linearity over the concentration range of 24_1 152 μmol/L(r2=0999). As to Tyr, the range of linearity was 22_1 056 μmol/L(r2=0998). The average analytical recoveries of added Phe and Tyr from blood were 98% and 96%, respectively. The limits of detection for Phe and Tyr were respectively 0.5 pg and 2.0 pg , which were 103 times lower than that of reported MS/MS method. About 40 blood samples were analyzed by this method, and the results proved that this method could successfully discriminate between normal infants and PKU positive ones. Each samples analysis time was about 4 minutes; therefore it was capable for large-scale screening.

关 键 词:氨基酸代谢 遗传病 新生儿 PDU 

分 类 号:R722.110.4[医药卫生—儿科] R446.112[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象