检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华东师范大学软件学院,上海200062 [2]中国科学院苏州纳米技术与纳米仿生研究所,江苏苏州215123
出 处:《传感器与微系统》2012年第4期99-102,共4页Transducer and Microsystem Technologies
摘 要:给出了一种基于电容式触觉传感器阵列的新型中医脉象采集系统的设计,弥补了以往单点压力传感器定位不准、信息量少、重复性差等缺点,目的是为中医脉象的客观化研究提供技术支持。本系统包括采集器软硬件、PC端软件设计以及基于斜率阈值的脉象起始点、主波峰值点特征提取方法。系统采集的脉象波形稳定,通过与人工标注的数据对比,特征提取算法的误差在0.02 s以内。A design of Chinese pulse collection system based on the tactile array sensor is given.It makes up the disadvantage of traditional single-point pressure sensors such as hard to locate,lack of information and hard to duplicate.The aim of this design is to offer technical support to the objective research of Chinese pulse and traditional Chinese medicine(TCM).The system includes the collector's hardware and software design,the software on PC and the feature extraction method of the onset and main wave peak value point of the pulse condition based on slope threshold.The pulse condition waveform collected by system is stable.By comparison with the manual marked data,the error extracted by the algorithm of feature extraction is less than 0.02s.
分 类 号:TP391.5[自动化与计算机技术—计算机应用技术]
正在载入数据...