摘 要:目的通过鼻咽癌常规放疗与适形放疗摆位误差的比较,找出摆位时存在的问题,并找出解决方法。方法以进行放射治疗的40例鼻咽癌患者为对象,20例患者接受常规外照射,另外20例行适形放疗,对其摆位误差进行分析。结果40例患者共拍摄120张射野验证片。常规放疗组摆位误差x轴(3.95±2.10)mm、Y轴(3.50±2.03)mm和Z轴(3.02±2.10)mm大于适形放疗组的x轴(1.78±1.03)mm、Y轴(1.53±0.92)mm和z轴(1.60±1.11)mm。结论通过严格的质量控制和采用适形放疗可以减少摆位误差,有效地提高摆位的雷傅忡.Objective To find and solve the setup problem by comparing of setup error between conventional radiotherapy and three-dimensional conformal radiatherapy for nasopharyngeal carcinoma ( NPC ). Methods 40 patients with NPC were assigned to receive con-centional radiotherapy ( 20 patients ) or 3D conformal radiotherapy ( 20 patients ). The setup errors of the two therapies were analyzed. Results One hundred and twenty films were obtained from all the 40 patients .The setup errors of conven- tional radiotherapy were significantly larger than those of 3D conformal radiatherapy in X , Y, and Z axis direction (3.95 ± 2.10 ram, 3.50±2.03 mm, and 3.02 ± 2.10 mm vs. 1.78 + 1.03 mm, 1.53 ± 0.92 mm, and 1.60 ± 1.11 mm ). Conclusions Setup errors carl be redueed by strict quality control and application of 31) conformal radiatherapy.